79
Chapter 6: Optional Components
Enabling NVMe RAID
RAID for NVMe SSDs must be enabled through the UEFI BIOS.
1. Install the patch as described in the Restrictions and Requirements section on a
previous page.
2. Reboot the server.
3. Press [DEL] key to enter BIOS.
4. Switch to
Advanced > Chipset Configuration > North Bridge > IIO Configuration >
Intel® VMD Technology > CPU3 & CPU4
.
5.
Enable
the VMD according to the following rules.
•
For U.2 NVMe, enable all the sub-items under each PStack, based on the your model
server:
•
For M.2 NVMe or NVMe AIC, enable the VMD according to which AOC card/slot it used.
Examples for some U.2 configurations follow.
6.
Press [F4] to save the configuration and reboot the system.
7. Press [DEL] to enter BIOS.
8. Switch to
Advanced > Intel(R) Virtual RAID on CPU > All Intel VMD Controllers >
Create RAID Volume
.
9. Set
Name
.
10. Set
RAID Level
.
11. If cross-controller RAID is required, select
Enable RAID spanned over VMD Controller
as shown in Figure 6-??.
12.
Select specific disks for RAID with an [X].
•
RAID0: Select at least two [2 - 24] disks
•
RAID1: Select only two disks
•
RAID5: Select at least three [3 - 24] disks
•
RAID10: Select only four disks