background image

USER’S MANUAL 

Revision 1.0b

SuperServer

®

SYS-240P-TNRT

Содержание SuperServer SYS-240P-TNRT

Страница 1: ...USER S MANUAL Revision 1 0b SuperServer SYS 240P TNRT ...

Страница 2: ...Class A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful interference with radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be require...

Страница 3: ... and utilities https www supermicro com wdl driver Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support supermicro com This manual may be periodically updated without notice Please check the Supermicro website for possible updates to the manual revision level Secure Data Deletion A secure data deletio...

Страница 4: ...Reference Table 17 Chapter 2 Server Installation 2 1 Overview 19 2 2 Unpacking the System 19 2 3 Preparing for Setup 19 Choosing a Setup Location 19 Rack Precautions 20 Server Precautions 20 Rack Mounting Considerations 20 Ambient Operating Temperature 20 Airflow 21 Mechanical Loading 21 Circuit Overloading 21 Reliable Ground 21 2 4 Installing the Rails 22 Installing the Inner Rails 22 Installing ...

Страница 5: ...e PHM 37 Removing the Processor from the Processor Carrier Assembly 38 3 5 Memory 39 Memory Support 39 Memory Installation Sequence 39 General Memory Population Requirements 39 DDR4 Memory Population Table 40 Memory Population Sequence for Half Memory Configuration 40 Memory Population Table with Full Memory Configuration 40 Intel Optane PMem 200 Series Memory Population Full Configuration 40 DIMM...

Страница 6: ...4 5 LED Indicators 67 4 6 Storage Ports 69 Chapter 5 Software 5 1 Microsoft Windows OS Installation 70 5 2 Driver Installation 72 5 3 SuperDoctor 5 73 5 4 BMC 74 BMC ADMIN User Password 74 Chapter 6 Optional Components 6 1 Optional Parts List 75 6 2 Storage Control Cards 76 6 3 Network Cards 76 6 4 Intel Virtual RAID on CPU VROC 77 Requirements and Restrictions 77 Supported SSDs and Operating Syte...

Страница 7: ...m Becomes Unstable 86 7 4 BIOS Error Beep POST Codes 88 Additional BIOS POST Codes 88 7 5 Crash Dump Using BMC 89 7 6 UEFI BIOS Recovery 90 Overview 90 Recovering the UEFI BIOS Image 90 Recovering the Main BIOS Block with a USB Device 90 7 7 CMOS Clear 95 7 8 Where to Get Replacement Components 96 7 9 Reporting an Issue 96 Technical Support Procedures 96 Returning Merchandise for Service 96 Vendor...

Страница 8: ...Website www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email Sales_Europe supermicro com Sales Inquiries Support_Europe supermicro com Technical Support RMA_Europe supermicro com RMA Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zho...

Страница 9: ... 2 5 NVMe SAS3 SATA3 drive bays Four optional rear 2 5 bays SAS SATA Two M 2 SATA3 Expansion Slots Up to 6 single wide PCIe 3 0 4 x16 2 x8 slots Up to 2 double wide PCIe 3 0 x16 slots for GPUs I O Ports Two 10G BaseT with Intel X710 TM4 Two 10G SFP with Intel X710 TM4 Optional AIOM up to 100G QSFP 28 One BMC port One VGA port One serial COM port Two rear USB 3 0 ports One USB 3 0 Type A header Sys...

Страница 10: ... in the table below For OS RAID or non RAID configurations some LED indications are not supported such as hot spare For VROC configurations refer to the VROC appendix in this manual Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Blue Solid On Idle SAS NVMe drive installed Blue Blinking I O activity Off Idle SATA drive Status LED Red Solid On Failure of drive w...

Страница 11: ... Fail LED Indicates a power supply module has failed Information LED Alerts operator to several states as noted in the table below Control Panel Figure 1 2 Control Panel Power Power LED Information LED UID Button LED BMC Reset HDD NIC LAN1 LED NIC LAN2 LED Power Fail LED Information LED Color Status Description Red solid An overheat condition has occurred Red blinking at 1Hz Fan failure check for ...

Страница 12: ... signal in x16 slot FHFL RSC D2R 668G4 7 PCIe 3 0 x16 signal in x16 slot HHHL RSC H2 68G4 optional 8 PCIe 3 0 x8 signal in x16 slot HHHL RSC H2 68G4 optional 9 PCIe 3 0 x16 signal in x16 slot HHHL RSC H2 68G4 optional 10 PCIe 3 0 x8 signal in x16 slot HHHL RSC H2 68G4 optional 11 PCIe 3 0 x16 AIOM OCP slot N A 7 8 6 5 4 3 2 1 Power Supply PWS1 10GBaseT LAN Ports USB Ports BMC LAN Port VGA Port COM...

Страница 13: ...High temperature Over voltage under voltage etc OFF 1Hz Blink Amber AC present only 12vsb on PS off 1Hz Blink Green OFF Output ON and OK Green OFF AC cord unplugged and in redundant mode OFF Amber System Features Rear Feature Description Power Supplies Two redundant power supply modules PWS1 on the left PWS2 on the right LAN Ports Two 10GBaseT and two 10G SFP LAN ports see Section 1 1 for details ...

Страница 14: ...M slots Dual in line memory module slots Processors Onboard 3rd Generation Intel Xeon Scalable processors System fans 8 cm heavy duty fans 1 3 System Architecture This section covers the locations of the system electrical components a system block diagram and a motherboard layout with the connectors and jumpers called out Main Components Power Supply Modules Fans 48 DIMM Slots 3rd Generation Intel...

Страница 15: ...E2 PE2 PE1 PE3 SLOT2 CPU1 PE3 x8 8 15 RUIO Riser CPU1 PE3 x8 0 7 CPU1 PE2 x16 CPU2 PE2 x8 0 7 CPU2 PE3 x16 P4_DIMMB1 P4_DIMMB2 P4_DIMMA1 P4_DIMMA2 P4_DIMMC1 P4_DIMMC2 DDR4 DIMM X2 DDR4 DIMM X2 DDR4 DIMM X2 DDR4 DIMM X2 DDR4 DIMM X2 DDR4 DIMM X2 P4_DIMMD1 P4_DIMMD2 P4_DIMME1 P4_DIMME2 P4_DIMMF1 P4_DIMMF2 P1_DIMMB1 P1_DIMMB2 P1_DIMMA1 P1_DIMMA2 P1_DIMMC1 P1_DIMMC2 DDR4 DIMM X2 DDR4 DIMM X2 DDR4 DIMM...

Страница 16: ... JCOM1 TPM PORT80 JLAN1 JLAN2 J55 J56 P2_PCIE3A P2_HIO_R1 PCIE 3 0 X16 P2_PCIE3B PDB_I2C2 RAID_KEY J58 JMD2 5V STBY PWR JSFP1 JSFP2 JSFP3 PCIE M 2 LAN4 LAN3 P2_PCIE2A JPWR7 BP_PWR3 VROC P4_PCIE3B BP_PWR1 P1_PCIE3B USB2 3 0 CPU1 LAN2 LAN1 COM1 P1_HIO_L1 PCIE 3 0 X16 P1_PCIE2B M 2 HC S SATA4 PCIE3 0X4 USB0 1 3 0 IPMI_LAN I SATA4 7 S SATA0 3 VGA M 2 HC S SATA5 PCIE3 0X4 CPU2 CPU3 UID P2_AIOM PCIE 3 0...

Страница 17: ...header for an BMC supported card BMC_LAN JUSBRJ45 Dedicated BMC LAN port J5 J6 6 pin power connector used for PCIe 3 0 x16 HIO left side slot P1_HIO_L1PCIE J5 power connector for right side slot P2_HIO_R1PCIE J6 J26 J47 PDB Power Delivery Board cable connector for CPU3 J47 PDB cable connector for CPU4 J26 JF1 Front Control Panel header JL1 Chassis Intrusion header BP_PWR1 2 3 8 pin power connector...

Страница 18: ...0 and 22110 support I SATA 0 3 I SATA 4 7 Intel PCH SATA 3 0 connectors 0 3 4 7 with RAID 0 1 5 10 S SATA 0 3 S SATA 3 0 Connector 0 3 supported by Intel PCH M 2 HC S SATA 4 5 JMD1 JMD2 PCIe 3 0 x4 M 2 slots for NVMe SATA SSDs with support of M Key 2280 and 22110 via SlimSAS x8 cables UID JUIDB1 Unit Identifier UID button USB0 1 3 0 JUSBRJ45 Rear I O USB 3 0 ports 0 1 USB2 3 0 JUSB1 Internal Type ...

Страница 19: ... the server It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated It will also require a grounded AC power outlet nearby Be sure to read the precautions and considerations noted in Appendix A 2 3 Preparing for Setup The box in which the system was shipped should include the rackmount hardware needed ...

Страница 20: ...ty precautions in Appendix A Determine the placement of each component in the rack before you install the rails Install the heaviest server components at the bottom of the rack first and then work your way up Use a regulating uninterruptible power supply UPS to protect the server from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and ...

Страница 21: ...ntion should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety This unit should be mounted at the bottom of the rack i...

Страница 22: ...ounting hardware provided You should also refer to the installation instructions that came with the specific rack you are using If you are installing into a two post telco rack skip to that section later in this chapter Installing the Inner Rails The chassis comes with two sets of rack rails one set for the right side of the chassis and one for the left Each set consists of an inner rail that atta...

Страница 23: ...it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack Take care that the proper holes are used so the rails are level If desired use screws to secure the rear of the outer rail to the rear of the rack 6 Repeat for the other outer rail Note The figure above is for illustrative purposes only Always install serve...

Страница 24: ...hassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed completely into the rack it should click into the locked position 4 Optional screws may be used to hold the front of the chassis to the rack Figure 2 3 Installing the Server into the Rack Notes Figure is for illustrative purposes only Always ...

Страница 25: ...ve sufficient assistance supporting the chassis when removing it from the rack Use a lift 1 If necessary loosen the thumb screws on the front of the chassis that hold it in the rack 2 Pull the chassis forward out the front of the rack until it stops 3 Press the release latches on each of the inner rails downward simultaneously and continue to pull the chassis forward and out of the rack ...

Страница 26: ...ction 3 1 Powering Down the System Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installing non hot swap components 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cord s from the power strip or outlet and remove the AC power cords from all power suppl...

Страница 27: ...de of the chassis Removing the Top Cover 1 Press the two release buttons and slide the cover toward the rear 2 Lift the top cover up Check that all ventilation openings on the top cover and the top of the chassis are clear and unobstructed Caution Except for short periods of time do not operate the server without the cover in place The chassis cover must be in place to allow for proper airflow and...

Страница 28: ...s Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any PCB printed circuit board from its antistatic bag Handle PCBs by their edges only do not touch its components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the PCBs back into their antistatic bags when not in use Use onl...

Страница 29: ... unplug the AC power cords from all power supplies Check that the plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling the processor avoid touching or placing direct pressure on the LGA lands gold contacts Improper installation or socket misalignment can cause serious damage to the processor or the socket and may re...

Страница 30: ...atic Sensitive Devices section earlier in this chapter 1 Hold the processor with the gold pins LGA lands facing down Locate the gold triangle at the corner of the processor and the corresponding hollowed triangle on the processor carrier as shown below These triangles indicate the location of pin 1 2 Turn the processor over with the gold pins up Locate the CPU keys on the processor and the four la...

Страница 31: ...ress the other end down until it snaps into latch 2 6 After the processor is placed inside the carrier examine the four sides of the processor making sure that the processor is properly seated on the carrier 3 Locate the lever on the carrier and press it down as shown below 4 Using pin 1 as a guide carefully align the CPU keys on the processor A B with those on the carrier a b as shown below Proce...

Страница 32: ... to the two triangle cutouts A B located at the diagonal corners of the heatsink as shown in the drawing below 2 Hold the processor carrier assembly upside down to locate the triangles on the processor and the carrier which indicate pin 1 3 Turn the processor carrier assembly over so that the gold pins are facing up Locate the two pin 1 locations A on the processor and a on the processor carrier a...

Страница 33: ...ocket for Installation The CPU socket comes with a plastic protective cover which needs to be removed before installing the Processor Heatsink Module PHM Do this by gently squeezing the grip tabs then pulling the cover off CPU Socket with Plastic Protective Cover Grip Tab ...

Страница 34: ... View Top View Unlatched State a b c d a b c d Threaded Fasteners CPU Socket Pin1 Threaded Fastener CPU Socket Installing the PHM into the CPU Socket After assembling the Processor Heatsink Module PHM you are ready to install it into the CPU socket 1 Locate four threaded fasteners a b c d on the CPU socket 2 Locate four peek nuts A B C D and four rotating wires 1 2 3 4 on the heatsink as shown bel...

Страница 35: ...e aligned gently place the heatsink on the CPU socket making sure that each peek nut is properly attached to its corresponding threaded fastener Latched State Top View Rotating Wire Rotating Wire 6 Press all four rotating wires outward and make sure that the heatsink is securely latched into the CPU socket C D A B 7 With a t30 bit screwdriver tighten all peek nuts in the sequence of A B C and D wi...

Страница 36: ... shut down the system and unplug the AC power cord from all power supplies 1 Use a t30 bit screwdriver to loosen the four peek nuts on the heatsink in the sequence of A B C and D A B C D PEEK Nut 2 Once the peek nuts have been loosened from the CPU socket press the rotating wires inward to unlatch the PHM from the socket as shown below 3 Gently lift the PHM upward to remove it from the CPU socket ...

Страница 37: ... please follow the steps below 1 Detach the four plastic clips marked a b c d on the processor carrier assembly from the four corners of the heatsink marked A B C D as shown below 2 When all plastic clips have been detached from the heatsink remove the processor carrier assembly from the heatsink Pin1 Pin1 A B C D a b c d Processor Carrier Assembly Heatsink ...

Страница 38: ...ssor from the processor carrier by following the steps below 1 Unlock the lever from its locked position and push it upwards to disengage the processor from the processor carrier as shown below right Lever Processor Carrier Assembly 2 Once the processor has been loosened from the carrier carefully remove the processor from the carrier Note Please handle the processor with care to avoid damaging it...

Страница 39: ...tabs General Memory Population Requirements 1 Be sure to use the memory modules of the same type and speed on the motherboard Mixing of memory modules of different types and speeds is not allowed 2 Using unbalanced memory topology such as populating two DIMMs in one channel while populating one DIMM in another channel will result in reduced memory performance 3 Populating memory slots with a pair ...

Страница 40: ...IMMB1 P3 DIMMB2 P3 DIMMA1 P3 DIMMA2 P3 DIMMD2 P3 DIMMD1 P3 DIMME2 P3 DIMME1 P3 DIMMF2 P3 DIMMF1 CPU4 12 DIMMs CPU4 P4 DIMMC1 P4 DIMMC2 P4 DIMMB1 P4 DIMMB2 P4 DIMMA1 P4 DIMMA2 P4 DIMMD2 P4 DIMMD1 P4 DIMME2 P4 DIMME1 P4 DIMMF2 P4 DIMMF1 DDR4 Memory Population Table Memory Population Table with Full Memory Configuration Symmetric Population 2 2 2 For Channel Configuration 2 2 2 Modes CPU1 P1 DIMMF1 P...

Страница 41: ... DIMMD1 P4 DIMME1 DIMM Population Order per CPU CPU1 C1 C2 B1 B2 A1 A2 D2 D1 E2 E1 F2 F1 1 DIMM X 2 DIMMs X X 3 DIMMs X X X 4 DIMMs X X X X 5 DIMMs X X X X X 6 DIMMs X X X X X X 7 DIMMs X X X X X X X 8 DIMMs X X X X X X X X 9 DIMMs X X X X X X X X X 10 DIMMs X X X X X X X X X X 11 DIMMs X X X X X X X X X X X 12 DIMMs X X X X X X X X X X X X Unbalanced configuration reduces performance and is not r...

Страница 42: ...Push both ends of the module straight down into the slot until the module snaps into place Notches Push both ends straight down into the memory slot DIMM Removal Press both release tabs on the ends of the DIMM module to unlock it Once the DIMM module is loose remove it from the memory slot 6 Press the release tabs to the lock positions to secure the DIMM module into the slot Warning To avoid causi...

Страница 43: ...n the motherboard Replacing the Battery Begin by removing power from the system 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the holder 2 To insert a new battery slide one edge under the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully D...

Страница 44: ...ermicro website product pages at https www supermicro com products nfo Ultra cfm Removing a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of the chassis Installing Drives The front of the system has 24 hard drive bays that support NVMe SAS3 and SATA3 hard drives...

Страница 45: ...ATA to aid in correct installation 3 Secure the drive to the carrier with four screws 4 Insert the drive carrier into its bay keeping the carrier oriented so that the hard drive is on the top of the carrier and the release button is on the right side When the carrier reaches the rear of the bay the release handle will retract 5 Push the handle in until it clicks into its locked position Note Your ...

Страница 46: ...SD 2 Select Device Group and Slot and click Eject After ejecting the drive Status LED indicator turns green 3 Remove the drive Note that Device and Group are categorized by the CPLD design architecture The SYS 240P TNRT server has one Device and one Group Slot is the slot number on which the NVMe drives are mounted Replacing the Drive 1 Insert the replacement drive 2 BMC System Storage Monitor Phy...

Страница 47: ...ystem from the rack are not intended to be used to pick up or lift the system Installing M 2 Drives 1 Power down the system as described in Section 3 1 2 Remove the system from the rack and place it on a bench then remove the cover as described previously 3 Begin by removing the riser brackets from the chassis 4 Insert the M 2 sideways into the connector so that it lays flat then secure it to the ...

Страница 48: ... earliest convenience with the same type and model the system can continue to run with a failed fan Changing a System Fan 1 Determine which fan has failed using BMC if possible If not remove the chassis cover while the power is on and examine the fans to determine which one has failed 2 Pull the system partially out from the rack 3 With the top cover partially pushed back depress the release butto...

Страница 49: ...led by CPUs 1 and 2 see figure below 1 Power down the system as described in Section 3 1 2 Remove the system from the rack and place it on a bench then remove the cover as described previously 3 Place each air shroud over six DIMM slots at a time for both CPU1 and CPU2 controlled DIMM slots as illustrated below 4 Close the cover and push the system back into the rack Figure 3 8 Installing Air Shro...

Страница 50: ...scribed in Section 3 1 2 Remove the system from the rack and place it on a bench then remove the cover as described previously 3 Place each air shroud over six DIMM slots at a time for both CPU3 and CPU4 controlled DIMM slots as illustrated below Close the cover and push the system back into the rack Figure 3 9 Installing Air Shrouds for CPU3 4 DIMMs Caution The handles used for pulling the system...

Страница 51: ...n 3 1 2 Remove the system from the rack and place it on a bench then remove the cover as described previously 3 Place the air shroud over the power supply connectors and secure with the screws and double sided tape included with the air shroud as illustrated below 4 Close the cover and push the system back into the rack Figure 3 10 Installing Air Shrouds for the Power Connections Caution The handl...

Страница 52: ...he cover as described previously 3 Remove the slimline SAS cable and pull up the riser card brackets For the right side looking from the node rear open the clip of each slot on the right For the left side open the clip of each slot 4 Remove the blank PCI shield from the chassis 5 Slide the expansion card shield into the open shield slot while plugging the expansion card into the riser card Figure ...

Страница 53: ...without powering down the system Replacement modules can be ordered directly from Supermicro An amber light on the power supply is illuminated when the power is switched off A green light indicates that the power supply is operating Replacing the Power Supply 1 Unplug the AC power cord from the failed power supply module 2 Push and hold the release tab on the back of the power supply 3 Grasp the h...

Страница 54: ...diagram when adding or replacing components so you can reroute them in the same manner Proper cable routing is important in maintaining proper airflow through the system Online Cable Matrix CPU1 to M 2 Slimline Cable CBL SAST 1244 85 CBL SAST 1235 85 SlimSAS to Backplane SATA Cable CBL SAST 1286 100 SlimSASLP to SlimSAS Riser Cable CBL SAST 120BLP 85 Backplane Power Cable CBL PWEX 0925 CPU2 to AIO...

Страница 55: ...he LED blinks at 2 Hz The BMC resets and the reset duration is 250 ms Then the BMC starts to boot Restore factory default configuration Hold the button for twelve seconds The LED blinks at 4 Hz while defaults are configured Firmware update the UID LED blinks at 10Hz during a firmware update BMC Reset Options Event LED Green Reset Blinks at 2 Hz Restore Defaults Blinks at 4 Hz Update Blinks at 10 H...

Страница 56: ..._PWR1 2 3 4 to the power supply Failure to do so may void the manufacturer warranty on your power supply and motherboard Backplane Power Connectors GPU Power Connectors In addition to the main power headers three 8 pin power connectors BP_PWR1 2 3 are used for backplane devices Another four 8 pin power connectors GPU_PWR1 2 3 4 are for GPU device use These 8 pin power connectors meet the ATX SSI E...

Страница 57: ...curity device that supports encryption and authentication in hard drives It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system For more information on TPM go to http www supermicro com manuals other TPM pdf VROC RAID Key Header A VROC RAID Key header is located at JRK1 on the motherboard For NVMe RAID support install a VROC RAID Key on JR...

Страница 58: ...stem Management Bus header for BMC is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2 C connection on your system Refer to the table below for pin definitions External I2 C Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Chassis Intrusion A Chassis Intrusion header is located at JL1 on the motherboard Attach the appropriate cable from the chass...

Страница 59: ...ugs into pin 1 as marked on the motherboard The other end connects to the control panel PCB board Power Button UID LED NIC1 Active LED Reset Button HDD LED PWR LED Reset PWR 3 3V Stby 3 3V Stby Ground 19 X Ground X 3 3V Stby 20 1 2 Ground Power Fail LED NIC2 Active LED NMI 3 3V OH Fan Fail PWR Fail LED 3 3V Stby Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Ground Power Button The Pow...

Страница 60: ...n has occurred This may be caused by cable congestion Blinking red 1Hz Fan failure check for an inoperative fan Blinking red 0 25Hz Power failure check for a non operational power supply Solid blue Local UID is activated Use this function to locate a unit in a rack mount environment that might be in need of service Blinking blue 300 msec Remote UID is on Use this function to identify a unit from a...

Страница 61: ...s 13 and 14 to show hard drive activity status Refer to the table below for pin definitions HDD LED Pin Definitions JF1 Pins Definition 13 3 3V Stdby 14 HDD Active LAN1 LAN2 LED Pin Definitions JF1 Pins Definition 9 NIC 2 Activity LED 11 NIC 1 Activity LED Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table below for pin definitions Power LED Pin Definitions J...

Страница 62: ...board These VGA connections provide analog interface support between the computer and the video displays COM Port A COM port that supports a serial link interface is included on the rear I O panel 10G LAN Ports LAN1 LAN2 LAN3 LAN4 BMC LAN Four 10G LAN ports LAN1 LAN2 LAN3 LAN4 and a dedicated BMC LAN port BMC LAN are located on the rear I O panel LAN1 LAN2 ports are supported by the RJ45 ethernet ...

Страница 63: ...Type A USB 2 3 0 Pin Definitions Pin Definition Pin Definition 1 VBUS 5 SSRX 2 USB_N 6 SSRX 3 USB_P 7 GND 4 Ground 8 SSTX 9 SSTX UID LED Pin Definitions Color Status Blue On Unit Identified Unit Identifier Switch and UID LED Indicator A Unit Identifier UID switch and a rear UID LED LED1 are located on the rear I O panel The front UID LED is located on pins 7 8 of the front panel control header JF1...

Страница 64: ...tely removed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS 1 First power down the system and unplug the power cord s 2 Remove the cover of the chassis to access the motherboard and remove the battery from the ...

Страница 65: ...Settings Jumper Setting Definition Pins 1 2 Reset Default Pins 2 3 NMI Open Disabled ME Select Jumper Settings Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 Manufacturer Mode Manufacturing Mode ME Mode Select Close pins 2 3 of jumper JPME2 to bypass SPI flash security and force the system to operate in manufacturing mode which will allow the user to flash the system firmware from a ho...

Страница 66: ...ion Power Failure Throttling Jumper Settings Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 Power Failure Throttling Enable Select Switch for FP1_Reset Button or UID Button Jumper J58 is used to select between the FP1_Reset button and the UID button The default setting is to close J58 to use the UID button Select Switch for FP1_Reset Button UID Button Jumper Settings Jumper Setting Def...

Страница 67: ...C LAN is also located on the rear I O panel The amber LED on the right indicates activity while the green LED on the left indicates the speed of the connection Refer to the table below for more information BMC LAN Activity LED Link LED LAN 1 LAN 2 IPMI LAN X8ST3 F BMC LAN LEDs Color State Definition Link left Green Solid Amber Solid 100 Mbps 1 Gbps Activity Right Amber Blinking Active 10G LAN3 4 L...

Страница 68: ...Onboard Power LED is located at LED2 When this LED is on the system power is on Be sure to turn off the system power and unplug the power cord before removing or installing components Onboard Power LED Indicator LED Color Definition Off System Power Off Green System Power On BMC Heartbeat LED A BMC Heartbeat LED is located at BMC_HB_LED1 on the motherboard When this LED is blinking the BMC is func...

Страница 69: ...s are supported by the Intel C621A chipset PCIe M 2 Slot M 2 HC S SATA4 5 Slots A PCIe 3 0 M 2 slot PCIE M 2 is located next to the TPM Port80 In addition two M 2 HC S SATA slots JMD1 JMD2 also support PCIe 3 0 x4 for NVMe SATA Solid State Devices SSDs These M 2 slots support 2280 and 22110 form factors via SlimSAS x8 cables required The M 2 slots allow for a variety of card sizes with increased f...

Страница 70: ... on our website at www supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a USB flash or media drive or the BMC KVM console 2 Retrieve the proper RST RSTe driver Go to the Supermicro web page for your motherboard and click on Download the Latest Drivers and Utilities select the proper driver and copy it to a USB flash dri...

Страница 71: ...river browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the SATA sSATA AHCI driver indicated then choose the storage drive on which you want to install it 5 Once all devices are specified continue with the installation 6 After the Windows OS installation has c...

Страница 72: ...nother option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or disk and the screenshot shown below should appear Figure 5 3 Driver Tool Installation Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the compu...

Страница 73: ...ia email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or BMC SuperDoctor 5 Management Server monitors HTTP FTP and SMTP...

Страница 74: ... are related to BMC For general documentation and information on BMC visit our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each system is assigned a unique default BMC password for the ADMIN user This can be found on a sticker on the chassis and a sticker on the motherboard The sticker also displays the BMC MAC address Figure 5 ...

Страница 75: ...wap 2 5 NVMe drive tray orange tab w key lock MCP 220 00127 0B 1 24 Black Gen3 hot swap 2 5 tool less SAS SATA HDD tray MCP 220 00147 0B 1 16 Add on Cards AOC VROCPREMOD AOC VROCSTNMOD CacheVaults BTR TFM8G LSICVM02 BKT BBU BRACKET 05 BTR TFM8G LSICVM02 MCP 240 00127 0N Network Cards AOC S40G i2Q AOC SGP i2 AOC SGP i4 AOC STG b4S AOC STGN i2S AOC STGN i1S AOC STG i2T AIOM Cards AOC AG i4SM AOC AG ...

Страница 76: ... SAS3 HDDs AOM TPM 9670V or AOM TPM 9671V n a TPM security module 6 3 Network Cards Network Card Options Part Number Description AOC S40G i2Q Standard LP 2 port 40GbE controller based on Intel Fortville XL710 AOC SGP i2 Standard LP 2x GbE RJ45 PCIe x4 Intel i350AM2 AOC SGP i4 Standard LP 4x GbE RJ45 PCIe x4 Intel i350 AOC STG b4S Standard LP 4x 10GbE SFP PCIe x8 Broadcom BCM57840S AOC STGN i2S Sta...

Страница 77: ...Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel RSTe Driver for Windows To enable Intel VROC a hardware key must be inserted on the motherboard and the ap propriate processor s Virtual Management Devices must be enabled in the BIOS setup It is pos...

Страница 78: ...The key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs AOC VROCPREMOD 951606 Intel SSD only RAID 0 1 5 10 Supports Intel SSDs only AOC VROCINTMOD 956822 Additional Information Additional information is available on the product page for the Supermicro ad...

Страница 79: ...ch PStack based on the your model server For M 2 NVMe or NVMe AIC enable the VMD according to which AOC card slot it used Examples for some U 2 configurations follow 6 Press F4 to save the configuration and reboot the system 7 Press DEL to enter BIOS 8 Switch to Advanced Intel R Virtual RAID on CPU All Intel VMD Controllers Create RAID Volume 9 Set Name 10 Set RAID Level 11 If cross controller RAI...

Страница 80: ...80 Chapter 6 Optional Components Figure 6 2 BIOS VMD Setting Examples ...

Страница 81: ...ithout enabling RAID spanned over VMD Controller Figure 6 4 Created Volume with enabling RAID spanned over VMD Controller 13 Select Strip Size Default 64KB 14 Select Create Volume 15 If another RAID is needed start again at step 6 16 Press F4 to save and reboot ...

Страница 82: ...device Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 2151404 2 https docs vmware com en VMware vSphere 6 5 com vmware vsphere storage doc GUID 1B56EF97 F60E 4F21 82A7 8F2A7294604D html 3 https docs vmware com en VMware vSphere 6 5 com vmware vsphere storage ...

Страница 83: ... BIOS BMC drivers etc FAQs RMA warranty and other service extensions Direct Links for the SYS 240P TNRT System SYS SYS 240P TNRT specifications page X12QCH P motherboard page for links to the Quick Reference Guide User Manual validated storage drives etc Direct Links for General Support and Information Frequently Asked Questions Add on card descriptions TPM User Guide General Memory Configuration ...

Страница 84: ...ystems motherboards power supplies riser cards add on cards etc Security Center for recent security notices Supermicro Phone and Addresses Direct Links continued 7 2 Baseboard Management Controller Interface The system supports the Baseboard Management interface BMC is used to provide remote access monitoring and management There are several BIOS settings that are related to BMC ...

Страница 85: ... on the motherboard is on CM CODE MAC CODE REV 1 01 BIOS LICENSE X12QCH PWRLED 3 Make sure that the power connector is connected to your power supply 4 Make sure that no short circuits exist between the motherboard and chassis 5 Disconnect all cables from the motherboard including those for the keyboard and mouse 6 Remove all add on cards 7 Install a CPU a heatsink connect the internal speaker if ...

Страница 86: ...se the same memory type and speed for all DIMMs in the system See Section 3 3 for memory details 3 Check for bad DIMM modules or slots by swapping modules between slots and noting the results 4 Check the power supply voltage 115V 230V switch Losing the System s Setup Configuration 1 Always replace power supplies with the exact same model that came with the system A poor quality power supply may ca...

Страница 87: ...e before or during OS installation check the following 1 Source of installation Make sure that the devices used for installation are working properly including boot devices such as CD 2 Cable connection Check to make sure that all cables are connected and working properly 3 Using the minimum configuration for troubleshooting Remove all unnecessary components starting with add on cards first and us...

Страница 88: ...onding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memory detected in system 5 long 2 short Display memory read write error Video adapter missing or with faulty memory 1 long continuous System OH System overheat condition Additional BIOS POST Codes The AMI BI...

Страница 89: ... provide information to support staff You can download a crash dump of status information using BMC Check BMC Error Log 1 Access the BMC web interface 2 Click the Server Health tab then Event Log to verify an IERR error checked BOM Figure 7 4 BMC Event Log In the event of an IERR the BMC executes a crash dump You must download the crash dump and save it ...

Страница 90: ...ted When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On Self Test routines Note 1 Follow the BIOS recovery instructions below for BIOS recovery when the main BIOS block crashes Note 2 When the BIOS recovery block crashes you will need to follow the procedu...

Страница 91: ...he BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use Note 2 Before recovering the main BIOS image confirm that the Super ROM binary image file you download is the same version or a close version meant for your motherboard 2 Insert the USB device that contains the new BIOS image Super ROM into your USB drive and reset the system when the following screen ap...

Страница 92: ...s shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt the BIOS flashing process until it has completed 5 After the BIOS recovery process is complete press any key to reboot the system 6 Using a different system extract the BIOS package into a USB flash...

Страница 93: ...UEFI Shell prompt appears type fs to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to start the BIOS update process 7 Press Del continuously during system boot to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot ...

Страница 94: ... complete When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously to enter the BIOS Setup utility 11 Press F3 to load the default settings 12 After loading the default settings press F4 to save the settings and exit the BIOS Setup utility ...

Страница 95: ...wn the system completely 2 Remove the cover of the chassis to access the motherboard 3 Remove the onboard battery from the motherboard 4 Short the CMOS pads with a metal object such as a small screwdriver for at least four seconds 5 Remove the screwdriver or shorting device 6 Replace the cover reconnect the power cords and power on the system Notes Clearing CMOS will also clear all passwords Do no...

Страница 96: ... boot block code 3 If you still cannot resolve the problem include the following information when contacting us for technical support System motherboard and chassis model numbers and PCB revision number BIOS release date version this can be seen on the initial display when your system first boots up System configuration An example of a Technical Support form is posted on our website Distributors F...

Страница 97: ...ilure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems Vendor Support Filing System For issues related to Intel use the Intel IPS filing system https www intel com content www us en design support ips training welcome html For issues related to Red Hat Enterprise Linux since it is a subscriptio...

Страница 98: ...r Website www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email Sales_Europe supermicro com Sales Inquiries Support_Europe supermicro com Technical Support RMA_Europe supermicro com RMA Support Website www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Z...

Страница 99: ...ring components in the Supermicro chassis These warnings may also be found on our website at http www supermicro com about policies safety_information cfm Warning Definition 警告の定義 この警告サインは危険を意味します 人身事故につながる可能性がありますので いずれの機器でも動作させる前に 電気回路に含まれる危険性に注意して 標準的な事故防止策に精通して下さい 此警告符号代表危险 您正处于可能受到严重伤害的工作环境中 在您使用设备开始工作之前 必须充分意识到触电 的危险 并熟练掌握防止事故发生的标准工作程序 请根据每项警告结尾的声明号码找到此设 备的安全性警告说明的翻译文本 此警告符號代表危險 您正處於可能身體可能會受...

Страница 100: ...l número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux cir...

Страница 101: ... risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい 警告 将此系统连接电源前 请先阅读安装说明...

Страница 102: ...내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voordat u het systeem op de voedingsbron aansluit サーキッ ト ブレーカー この製品は 短絡 過電流 保護装置がある建物での設置を前提としています 保護装置の定格が250 V 20 Aを超えないこ とを確認下さい 警告 此产品的短路 过载电流 保护由建筑物的供电系统提供 确保短路保护设备的额定电流不大于 250V 20A 警告 此產品的短路 過載電流 保護由建築物的供電系統提供 確保短路保護設備的額定電流不大於 250V 20A Warning This product relies on the building s installation for short circuit overcurrent protectio...

Страница 103: ...ension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging overspanning van uw electrische installatie Controleer of het beveiligde apara...

Страница 104: ...r zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d accéder à ...

Страница 105: ...lace or service this equipment 機器の設置 トレーニングを受け認定された人だけがこの装置の設置 交換 またはサービスを許可されていま す 警告 只有经过培训且具有资格的人员才能进行此设备的安装 更换和维修 警告 只有經過受訓且具資格人員才可安裝 更換與維修此設備 Warnung Das Installieren Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo امداد وحدة من انكهرباء سهك انت ...

Страница 106: ...管制區域 進出管制區域係指僅能以特殊工具 鎖頭及鑰匙或其他安全 方式才能進入的區域 Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and key or other means of security This ...

Страница 107: ...ès réservés L accès à une zone d accès réservé n est possible qu en utilisant un outil spécial un mécanisme de verrouillage et une clé ou tout autre moyen de sécurité 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkrege...

Страница 108: ... incorrecta Reemplazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante 電池の取り扱い 電池交換が正しく行われなかった場合 破裂の危険性があります 交換する電池はメーカーが推 奨する型 または同等のものを使用下さい 使用済電池は製造元の指示に従って処分して下さ い 警告 电池更换不当会有爆炸危险 请只使用同类电池或制造商推荐的功能相当的电池更换原有电 池 请按制造商的说明处理废旧电池 警告 電池更換不當會有爆炸危險 請使用製造商建議之相同或功能相當的電池更換原有電池 請按 照製造商的說明指示處理廢棄...

Страница 109: ...upplies Warning This unit might have more than one power supply connection All connec tions must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さなければなりません 警告 此部件连接的电源可能不止一个 必须将所有电源断开才能停止给该部件供电 警告 此裝置連接的電源可能不只一個 必須切斷所有電源才能停止對該裝置的供電 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugeführt wir...

Страница 110: ...exión para fuentes de alimentación Para cortar por completo el suministro de energía deben desconectarse todas las conexiones Attention Cette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées אחד מספק יותר קיים אם אזהרה לרוקן מנת על החיבורים כל את להסיר יש ספק של אחד ...

Страница 111: ... bei der Wartung Advertencia Cuando el sistema está en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use cauti...

Страница 112: ...에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Attention L équipement doit être installé conformément aux normes électriques nationales et locales 警告 设备安装必须符合本地与本国电气法规 警告 設備安裝必須符合本地與本國電氣法規 Warning Installation of the equipment must comply with loc...

Страница 113: ...有國家的法律和規章進行 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according to all national laws and regulations Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales הארצי החשמל חוקי תיאום אזהרה והארציים המקומיים החשמל לחוקי תואמת להי...

Страница 114: ...eep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing ファン ホッ トスワップの警告 警告 回転部品に注意 運転中は回転部 羽根 に触れないでく ださい シャーシから冷却ファン装 置を取り外した際 ファンがまだ回転している可能性があります ファンの開口部に 指 ドライバ ー およびその他のものを近づけないで下さい 警告 警告 危险的可移动性零件 请务必与转动的风扇叶片保持距离 当您从机架移除风扇装置 风扇可能仍在转动 小心不要将...

Страница 115: ...enez garde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur 경고 움직이는 위험한 부품 회전하는 송풍 날개에 접근하지 마세요 섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다 팬 조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버 다른 물체들이 가까이 하지 않도록 배치해 주십시오 Waarschuwing Gevaarlijk bewegende onderdelen Houd voldoende afstand tot de bewegende ventilatorbladen Het is mogelijk dat de ventilator nog draait tijdens he...

Страница 116: ...下さい 他のケー ブルやアダプタを使用すると故障や火災の原因になるこ とがあります 電気用品安全法は ULまたはCSA認定のケーブル UL CSAマークがコードに表記 を Supermicro が指定する製品以外に使用するこ とを禁止しています 警告 安装此产品时 请使用本身提供的或指定的或采购的连接线 电源线和电源适配器 包含遵照当 地法规和安全要求的合规的电源线尺寸和插头 使用其它线材或适配器可能会引起故障或火灾 除了Supermicro所指定的产品 电气用品和材料安全法律规定禁止 使用未经UL或CSA认证的线材 线材上会显示UL CSA符号 警告 安裝此產品時 請使用本身提供的或指定的或採購的連接線 電源線和電源適配器 包含遵照當 地法規和安全要求的合規的電源線尺寸和插頭 使用其它線材或適配器可能會引起故障或火災 除了Supermicro所指定的產品 電氣用品和材料安全法律規定禁止 ...

Страница 117: ... שמתשהל םילבכב םיכמסומה ב UL וא ב CSA רשאכ עיפומ םהילע דוק לש UL CSA רובע לכ רצומ ילמשח רחא אלא קר רצומב רשא םאתוה י ע Supermicro דבלב دنع بيكرت جتنملا مق مادختساب تاليصوتلا ةرفوتملا وأ ةددحملا وأ مق ءارشب تالباكلا ةيئابرهكلا تالوحمو رايتلا ددرتملا عم مازتلالا نيناوقب تابلطتمو ةمالسلا ةيلحملا امب يف كلذ مجح لصوملا سباقلاو ميلسلا مادختسا يأ تالباك تالوحمو ىرخأ دق ببستي يف لطع وأ قيرح رظحي نوناق ةما...

Страница 118: ...n van het Product uitsluitend gebruik maken van de geleverde Kabels of een andere geschikte aan te schaffen Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of brand veroorzaken Wetgeving voor Elektrische apparatuur en Materiaalveiligheid verbied h...

Страница 119: ...CPMM Storage Drives 24 hot swap 2 5 NVMe SAS3 SATA3 drive bays Four optional rear 2 5 bays SAS SATA Two M 2 NVMe SATA3 PCI Expansion Slots Up to 6 single wide PCIe 3 0 4 x16 2 x8 slots or Up to 2 double wide PCIe 3 0 x16 slots for GPUs Input Output Network Two 10G BaseT with Intel X710 TM4 2x 10G SFP with Intel X710 TM4 and optional AIOM up to 100G QSFP 28 BMC Dedicated LAN port USB Two rear USB 3...

Страница 120: ...0 60 Hz Rated Output Power 1000W 100 127Vac 1800W 200 220Vac 1980W 220 230Vac 2000W 230 240Vac 2000W 220 240Vac UL only Rated Output Voltages 12V Max 83A Min 0A at 1000W Max 150A Min 0A at 1500W Max 165A Min 0A at 1980W Max 166A Min 0A at 2000W Max 166A Min 0A at 2000W China only 12Vsb Max 3 5A Min 0A Operating Environment Operating Temperature 10º to 35º C 50º to 95º F Non operating Temperature 4...

Страница 121: ... EN BS 61000 4 8 EN BS 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD Directive UL CSA 60950 1 2nd Edition UL CSA 62368 1 USA and Canada IEC EN 62368 1 IEC 60950 1 2nd Edition Perchlorate Warning California Best Management Practices Regulations for Perchlorate Materials This Perchlorate war...

Страница 122: ... 備考2 係指該項限用物質之百分比含量未超出百分比含量基準值 備考3 係 指該項限用物質為排除項目 Declaration of the Presence Condition of the Restricted Substances Marking Equipment name Type designation Type Restricted substances and its chemical symbols Note 1 Exceeding 0 1 wt and exceeding 0 01 wt indicate that the percentage content of the restricted substance exceeds the reference percentage value of presence condition Note 2 indicates th...

Страница 123: ... Chinese Safety Warnings 輸 輸入 入額 額定 定 100 127V 60 50Hz 12 9A 200 240V 60 50Hz 10 9 8A 使用者不能任意拆除或替換內部配備 報驗義務人之姓名或名稱 美超微電腦股份有限公司 報驗義務人之地址 新北市中和區建一路 150 號 3 樓 警告使用者 此為甲類資訊技術設備 於居住環境中使用時 可能會造成射頻擾動 在此種情況下 使用者會被要求採取某些適當的對策 ...