Chapter 5: Interface Configuration
Saving Power
– 140 –
consumption can be reduced since signal attenuation is proportional
to cable length. When power-savings mode is enabled, the switch
analyzes cable length to determine whether or not it can reduce the
signal amplitude used on a particular link.
N
OTE
:
Power savings can only be implemented on Gigabit Ethernet ports
when using twisted-pair cabling. Power-savings mode on a active link only
works when connection speed is 1 Gbps, and line length is less than 60
meters.
P
ARAMETERS
These parameters are displayed:
•
Port
– Power saving mode only applies to the Gigabit Ethernet ports
using copper media.
•
Power Saving Status
– Adjusts the power provided to ports based on
the length of the cable used to connect to other devices. Only sufficient
power is used to maintain connection requirements. (Default: Enabled
on Gigabit Ethernet RJ-45 ports)
W
EB
I
NTERFACE
To enable power savings:
1.
Click Interface, Green Ethernet.
2.
Mark the Enabled check box for a port.
3.
Click Apply.
Figure 5-37: Enabling Power Savings
Содержание SSE-G2252
Страница 42: ...44 General IP Routing on page 627...
Страница 174: ...Chapter 6 VLAN Configuration Configuring VLAN Mirroring 178 Figure 6 27 Showing the VLANs to Mirror...
Страница 511: ...Chapter 14 Basic Administration Protocols UDLD Configuration 518 Figure 14 100 Displaying UDLD Neighbor Information...
Страница 603: ...Chapter 16 IP Configuration Setting the Switch s IP Address IP Version 6 609...
Страница 883: ...Chapter 24 General Security Measures Port based Traffic Segmentation 894...
Страница 989: ...Chapter 30 Congestion Control Commands Automatic Traffic Control Commands 1000 Console...
Страница 1007: ...Chapter 33 Address Table Commands 1019...
Страница 1137: ...Chapter 38 Quality of Service Commands 1150...
Страница 1366: ...Chapter 46 IP Routing Commands Global Routing Configuration 1381 Connected 2 Total 2 FIB 0 Console...