65
Parameter
Description
Adjustment ratio (%)*
If the adjustment does not reach the set target value,
increase or decrease adjustment value according to the set
adjustment ratio, so as to reach the target value.
Control cycle
Time interval of delivering dispatching instructions
Parameter range: 5~60s
Note: *Only when the control method is set to
Closed-loop control
, the parameter
Select
energy meter / transformer
is settable.
step 4 After finishing parameter setting, click
Save
to save the operation.
- - End
8.3.1.3 Local Power Control
If active dispatching instruction or dispatching target value is used as dispatching input
locally, the active control mode is set to
Local power control
.
step 1 Click
Power control→Active power
to enter the active power interface.
step 2 Set the active control mode to
Local power control
.
step 3 Set local dispatching parameters. For specific parameter description, refer to the following
table.