Страница 1: ...DL75 DATA LOGGER SYSTEM instructions D A T A L O G G E R S Y S T E M i n str u c t i o n s The Leader in Flow Meter Value A R C H I V E D 2 0 1 0 8 ...
Страница 2: ...e laptop or easily loaded onto a desktop computer for analysis SeaMetrics FlowInspector software allows the downloading storing viewing graphing charting and printing of data in several formats FlowInspector requires a PC with Windows 98 NT 2000 or XP CD Rom drive 800 x 600 screen reso lution serial port or USB serial adapter and a SeaMetrics DC3 data cable SPECIFICATIONS 3 6 Vdc lithium battery i...
Страница 3: ...in place of the meter cover and tighten the screws evenly The gasket on the DL75 should be visibly compressed by tightening all around MOUNTING and CONNECTIONS 2 82 3 95 4 52 3 35 2 06 3 95 DL75 Data Logger Data Port Active Replace Battery 4 90 3 16 DL75W WALL MOUNT DIMENSIONS DL75M METER MOUNT battery dl75 to insertion magmeter connections see also next page Magmeter Terminal Block S Caution Do n...
Страница 4: ...t No flow rate DL75 is transmitting data Wait two minutes before taking action Dead battery in DL75 Loose cable Bad cable K factor setting is incorrect Damaged flow sensor Broken wire Wait for Active light to blink Replace battery Tighten cable Replace cable Make sure K factor in DL75 matches flow sensor Mechanical See if rotor spins freely EX Magmeter See if Status LED indicator is blinking Check...