27
figure 5-2
Connection to PV background system
Default IP of the "ETH": IP12.12.12.12.
- - End
5.5
Connection to Micro-SIM
Micro-SIM card size: 12mmx15mm.
Support of hot plug of Micro-SIM.
5.6
Connection to Power Box
The Logger1000 supports DC24V power supply. Prepare two-core DC cable, three-core AC
cable, and grounding cable before wiring. Power cable specifications are shown in the table
below.
table 5-2 Power cable specification
Cable
Recommended
cross-section
Length of cable
jacket to be
stripped off
Length of
insulation to be
stripped off
DC cable, AC cable
1mm
2
~1.5mm
2
15mm
8mm~10mm
Grounding cable
1mm
2
~1.5mm
2
8mm~10mm
-