Page 80
980™ Series
18.5 Dual Service 50Hz Connection
Wiring for export models with dual service breakers. The jumper wiring is
shown below.
18.6 Single Service 50Hz Connection
Wiring for export models with a single service breaker. The jumper wiring
is shown below. The included extra White wire (1*)
must
be installed.
Dual Service Jumper Wiring
Wire
From
To
1
J33
J51
2
J59
J38
3
J37
J53
4
J45
J3
5
J42
J4
1
2
4
3
TB1
D
C
B
A
J51
J3
J49
J59
J44
J37
J38
J53
J60
J66
J45
J46
J47
J41
J58
J42
J31
J32
J33
J40
J64
J36
J35
1
2
3
4
GRN
N2
BLU
L1 BRN
N1 BLU
L2 BRN
DUAL
SERVICE
16A MAX.
J65
J4
5
WIRE
FROM
TO
1
J33
J51
2
J59
J38
3
J37
J53
4
J37
J53
5
J45
J3
J42
J4
DUAL SERVICE WIRING
FACTORY DEFAULT
4
3
TB1
D
C
B
A
J51
J3
J49
J59
J44
J37
J38
J53
J60
J66
J45
J46
J47
J41
J58
J42
J31
J32
J33
J40
J64
J36
J35
1
2
3
4
GRN
L1 BRN
N1 BLU
SINGLE
SERVICE
J65
J4
5
6
2
1*
WIRE
FROM
TO
1
J33
J47
2
J59
J41
3
J37
J36
4
J46
J51
5
J45
J3
6
J42
J4
SINGLE SERVICE WIRING
Single Service Jumper Wiring
Wire
From
To
1*
J33
J47
2
J59
J41
3
J37
J36
4
J46
J51
5
J45
J3
6
J42
J4
*Extra connection must be
made
BREAKER TERMINAL
CONNECTIONS
L1 = Heater/Blower/Lighting
L2 = All other components
BREAKER TERMINAL
CONNECTIONS
L1 = All components