Summer Logic:
In warm weather, the water temperature in the spa
may exceed the set temperature. This condition may occur due to heat
transference from the filter/circulation pump and jets pumps. If the
water temperature is higher than 95°F (35°C) and rises two degrees
above the set temperature, a “Summer Logic” condition occurs that
deactivates the filter/circulation pump and CLEAR
RAY
. This safety
feature cannot be altered! The filter/circulation pump and CLEAR
RAY
will remain off until the water temperature cools to the set temperature
(except between 9AM-11AM when the filter/circulation pump runs
for it’s mandatory 2 hour cycle.) To help prevent a “Summer Logic”
condition, it may be necessary to reduce filter/circulation pump cycles
run times in warm weather.
12.4 Programming the Secondary Filtration
To access the “Secondary” feature, tap
Secondary...
from the Heat and
Filter Menu, Figure 12.4a, to enter the “Secondary” programming, Figure
12.4b.
During a secondary filtration, the Jets Pump 1 is activated. There are
3 cycles you can select from, Figure 12.4b. The factory default cycle is
“Away.” If you elect to keep this setting, then you can skip this section.
A.
To change the Secondary Filter cycle:
1. Infrequent Mode: Activates two cycles at 8:00 PM and 8:00 AM
every
other day
. Each cycle will last 10 minutes for a total of 20 minutes
every other day. To activate this mode, tap the “Infrequent” tab. Time
and duration cannot be altered.
2. Frequent Mode: Activates two cycles at 8:00 PM and 8:00 AM
every
day
. Each cycle will last 10 minutes for a total of 20 minutes every
day. To activate this mode, tap the “Frequent” tab. Time and duration
cannot be altered.
3. Away Mode: Secondary Filtration is disabled. To activate this mode,
tap the “Away” tab. This is the factory default setting.
4. Tap to return to the Heat and Filter Menu. Tap again to return to
the Settings Menu.
6:45
Heat & Filter
Day
Primary...
Secondary...
Auto
6:45
Filter 2
Infrequent
Frequent
Away
Auto
Figure 12.4b