Page 17
980™ Series
7.2
Export 50 Hz Power Options
Export 50 Hz (1 Breaker Connection)
Main
Terminal Breaker
(including Heater)*
Main
Terminal Breaker
(including Heater)**
Voltage:
230 VAC
230 VAC
Max. Current Draw:
19A
31A
Wattage:
4.4kW
7.2kW
Frequency:
50 Hz
50 Hz
Number of Wires:
3
3
* In this configuration, the heater
will not operate
while any jets pump is
running. The configuration will include connection for pumps, circulation
pump, blower, CLEAR
RAY
, lighting, stereo (optional), ozone (optional)
and heater.
** In this configuration, the heater
will operate
while two jets pumps are
running.
The configuration will include connection for pumps, circulation
pump, blower, CLEAR
RAY
, lighting, stereo (optional), ozone (optional)
and heater.
Export 50 Hz (Two and Three Breaker Connections)
Terminal Breaker 2/
Main Heater Terminal
Breaker***
Terminal Breaker 2/
Terminal Breaker 3/
Main Heater Terminal
Breaker****
Voltage:
230 VAC
230 VAC
Max. Current Draw:
17A/15A
9A/9A/15A
Wattage:
3.9kW/3.5kW
2.1kW/2.1kW/3.5kW
Frequency:
50 Hz
50 Hz
Number of Wires:
5
5
***
In this configuration, the heater
will operate
while all jets pumps are
running.
This is the factory default setting.
The main breaker (L1)
will include connections for heater, blower and lighting. The second-
ary breaker (L2) will include connections for pumps, circulation pump,
CLEAR
RAY
, stereo (optional) and ozone (optional).
**** In this configuration, the heater
will operate
while all jets pumps are
running. The main breaker (L1) will include connections for the heater,
blower and lighting. The secondary breaker (L2) will have connections
for pump 1, circulation pump, and ozone (optional). The third breaker
(L3) will include connections for pump 2, CLEAR
RAY
and stereo (op-
tional).
Содержание Claremont 980 Series
Страница 1: ...P N 6530 397D Rev A 980 Series Owner s manual Kingston Claremont...
Страница 6: ......
Страница 88: ...Page 82 980 Series...