![Sundance Spas Claremont 980 Series Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/sundance-spas/claremont-980-series/claremont-980-series_owners-manual_1395384076.webp)
Page 70
980™ Series
8. Frozen on Start-up: Flow switch is non-functional. Shorted flow
switch on system start-up (system disabled) and freeze condition
detected. Contact your authorized dealer or service organization.
9. Cool Warning: Spa water is more than 20°F/-6.67°C cooler than
the temperature set point, the circulation pump and heater will
automatically activate to provide freeze protection. The spa will stay
in this mode until the water temperature reaches 15°F/-9.44°C below
the set temperature. No corrective action is necessary.
Note:
The heater icon will be blinking and the error icon will be
displayed under the temperature.
10. Freeze protection: A potential freeze condition has been detected. No
action is required. Jets pump(s) operate until the spa is out of danger.
No corrective action is necessary. If condition persists, contact your
authorized dealer or service organization.
11. Overheat protection:
DO NOT ENTER THE WATER!
Water
temperature is above acceptable limits. Heater is deactivated.
Remove the spa cover to speed cooling. If condition persists, contact
your authorized dealer or service organization.
Note:
The heater icon will be blinking and the error icon will be
displayed under the temperature.
12. Watchdog Protection:
DO NOT ENTER SPA!
Water temperature is
above acceptable limits. Your
spa is deactivated. Remove the spa
cover to speed cooling. If condition persists, contact your authorized
dealer or service organization.
Note:
The heater icon will be blinking and the error icon will be
displayed under the temperature.
13. Watchdog Freeze Protection: Spa water is below 40°F/4.4°C. Jet
pumps operate until the spa is out of danger. Contact your authorized
dealer or service organization.
Note:
The heater icon will be blinking and the error icon will be
displayed under the temperature.
14. Controller Overheat Protection: Controller temperature has exceeded
acceptable limits. If condition persists, provide shade for equipment
side of spa. Contact your authorized dealer or service organization.
Note:
The heater icon will be blinking and the error icon will be
displayed under the temperature.
WARNING:
RISK OF HYPERTHERMIA (OVER-HEAT-
ING) CAUSING SEVERE INJURY, BURNS, OR WELTS.
!
WARNING:
RISK OF HYPERTHERMIA (OVER-HEAT-
ING) CAUSING SEVERE INJURY, BURNS, OR WELTS.
!
Содержание Claremont 980 Series
Страница 1: ...P N 6530 397D Rev A 980 Series Owner s manual Kingston Claremont...
Страница 6: ......
Страница 88: ...Page 82 980 Series...