Page 66
980™ Series
14.4 CLEARRAY Bulb Replacement and Quartz Tube Maintenance
Important:
It is
MANDATORY
that the UV bulb is replaced and the
quartz tube be cleaned every 12 months to maintain optimum
performance.
!
DANGER:
TURN THE SPA BREAKER TO THE OFF
POSITION!
!
WARNING:
DRAIN THE SPA IF YOU ARE REPLACING OR
CLEANING THE QUARTZ TUBE!
!
WARNING:
ALLOW LAMP TO COOL DOWN PRIOR TO
REMOVING FROM QUARTZ TUBE.
!
DANGER:
NEVER LOOK AT THE LIT BULB. THIS CAN
CAUSE SEVERE EYE DAMAGE OR BLINDNESS.
UV bulb replacement and quartz tube maintenance:
Note:
Location of CLEAR
RAY
System and connection may vary by
model.
1. Turn the breaker to the spa OFF. DRAIN YOUR SPA.
Note:
If you are only replacing the UV bulb then the spa
does not have to be drained. You will need to drain it if you
are replacing or cleaning the quartz tube.
2. Once the UV bulb has cooled off remove the
CLEAR
RAY
System enclosure cover (2) by removing
the four screws (1). This will expose the UV bulb and
connections, Figure 2.
1
2
3
4
7
5
8
9
11
12
10
6
#3 shown as reference only.
It is attached to the #10 metal plate.
FIGURE 1
DANGER:
NEVER REMOVE COVER WITHOUT FIRST
TURNING OFF AT POWER SOURCE AND DRAINING THE
SPA.
!
FIGURE 2