![Sundance Spas Claremont 980 Series Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/sundance-spas/claremont-980-series/claremont-980-series_owners-manual_1395384080.webp)
Page 74
980™ Series
17.0 Typical Hot Tub Wiring Diagrams A-B (North American
60 Hz Models Only)
DANGER
Turn power off
before servicing. This
task should only be
performed by a quali-
fied technician.
!
RISK OF SHOCK OR
ELECTROCUTION!
Red (L2)
Pigtail
Neutral Bus
Ground
Black (L1)
Green**
Main
Service
Panel
with
GFCI
2-Pole
GFCI
Breaker
Ground/Bonding Lug**
2-Pole Circuit Breaker with 2-Wire Grounded Load Connection
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
White (N)
Black (L1)
Red (L2)
240 VAC
No Load Neutral Wire
Note: service disconnect not
shown in this diagram.
Red (L2)
Red (L2)
Pigtail
Neutral Bus
Ground
Black (L1)
Black (L1)
Green**
GFCI Sub Panel*
Main Panel*
2-Pole
GFCI
Breaker
Ground/Bonding
Lug**
No Load Neutral Wire
Main Panel with Secondary GFCI Shut-Off Box Using a
2-Pole GFCI Breaker with 2-Wire Grounded Connection
(3 Wires to Hot Tub, 2-Hot (L1-L2), 1-Ground)
White (N)
Green (Ground)
*GFCI Sub Panel commonly
used when recommended GFCI
does not install in Main Panel.
Note: service disconnect not
shown in this diagram.
B
A
240 VAC
Содержание Claremont 980 Series