3-20
Sun Netra X4450 Server Service Manual • August 2008
3.6
Replacing System Fan 0
System fan 0 is labeled FT0 and is located at the front of the chassis.
▼
Remove System Fan 0
1. Prepare the server for fan assembly removal.
See
Chapter 2
.
2. Insert your forefinger and thumb into the holes at the top of the fan assembly,
squeeze them together, and lift the fan assembly from the chassis (
FIGURE 3-15
).
FIGURE 3-15
Lifting System Fan 0 From the Chassis
3. Set the fan assembly on an antistatic mat.
4. Consider your next step:
■
If you removed the fan assembly as part of another procedure, return to that
procedure.
■
Otherwise, continue to
“Install System Fan 0” on page 3-21
.
▼
Install System Fan 0
1. Remove the replacement fan assembly from its packaging, and place it on an
antistatic mat.