Chapter 3
Replacing Components
3-17
▼
Locate a Faulty FB-DIMM
The system Service Required Indicator lights if the system detects a FB-DIMM fault.
See
Section 1.2.1 “Memory Fault Handling” on page 1-4
.
1. Prepare the server for FB-DIMM removal.
See
Chapter 2
.
2. Press the FB-DIMM fault locator button.
The button is located on the left edge of the memory mezzanine.
3. Note the location of faulty FB-DIMMs.
Faulty FB-DIMMs are identified with a corresponding amber indicator.
Note –
The FB-DIMM fault indicator remains lit only for a few minutes.
4. Ensure that all FB-DIMMs are seated correctly in their slots.
▼
Remove FB-DIMMs
1. If you have not already done so, prepare the server for FB-DIMM removal.
See
Chapter 2
.
2. Push down on the ejector tabs on each side of the FB-DIMM until the
FB-DIMM is released (
FIGURE 3-13
).