B-8
Sun Fire E2900 System Service Manual • May 2006
B.6
Alarms Port
The alarms service port connector (
) is a male DB-15 connector.
lists the pinouts.
FIGURE B-6
DB-15 (Male) Alarms Service Port Connector
TABLE B-7
DB-15 (Male) Alarms Service Port Connector
Pin
Signal Name
Description
State
1
Not connected
2
Not connected
3
Not connected
4
Not connected
5
SYSTEM_NO
UNIX Running
Normally open
6
SYSTEM_NC
UNIX Running
Normally closed
7
SYSTEM_COM
UNIX Running
Common
8
SYSTEM_NO
Alarm1
Normally open
9
SYSTEM_NC
Alarm1
Normally closed
10
SYSTEM_COM
Alarm1
Common
11
ALARM2_NO
Alarm2
Normally open
12
ALARM2_NO
Alarm2
Normally closed
13
ALARM2_COM
Alarm2
Common
14
Not connected
15
Not connected
8
1
9
15