64
12.3 Boiler history
The boiler history found in the information menu displays several history counters that keep track of the boiler
usage. The history cannot be erased and will continue for the burner controller life cycle. The following boiler
history data is available:
(Sub) Menu item
Description
Successful Ignitions
Number of successful ignitions.
Failed Ignitions
Number of failed ignitions.
Flame Failures
Number of flame failures (loss of flame).
Operation Days
Number of days that the appliance is operational (powered ON).
CH Burner Hours
Number of hours that the appliance has burned for Central Heating.
DHW Burner Hours
Number of hours that the appliance has burned for Domestic Hot Water.
12.4 Error logging.
Error logging is available. This functionality is linked to the Real-Time Clock functionality.
Errors will be logged for a stand-alone system or for a complete cascade system (based on the cascade settings).
The PB display will monitor the error codes it receives from the boiler(s) and if an error code is a new error code
the error will be stored in the error log. An error will be logged with a (real-time clock) time stamp (date and time)
when the error was detected and a boiler ID of the boiler on which the error was detected.
The error log can be viewed from the error log menu, which is located in the information menu.
Menu
Domestic Hot Water (DHW)
Information
Settings
System test
i
Information
Boiler Status
Boiler History
Error Log
Service
!
Error Log
Error Log
Filter Error Type
Clear Error Log
Disabled
(Sub) Menu item
Description
Error Log
Show the error log (based on the selected filter options)
Filter Error Type
Filter errors based on the Error Type (Lockout/Blocking)
Filter Boiler ID (Cascade System only) Filter errors based on Boiler ID (Managing, Dep 1, Dep 2, etc.)
Clear Error Log
Clear the error log (protected by password)
When no filtering option is selected (Disabled) the error log will show all errors for that category. So, if both filters
are disabled, the error log will show all the errors in the log.
Error Log
A014 (14) Lockout
Air Switch Not Closed
Wed 04-11-2018 14:50 1/32 ▼
Содержание S-CBX 105
Страница 2: ......
Страница 40: ...40 9 10 Flue Terminal Positioning ...
Страница 42: ...42 9 11 1 FIGURE 12 LINE G ...
Страница 55: ...55 11 5 Ladder Logic Diagram ...
Страница 56: ...56 11 6 Electrical schematics ...
Страница 57: ...57 ...
Страница 137: ......