TIP 5000: Tape Drives
3-18
Fifth Edition
95897
Drive makes a flip sound. All
lights on right front of drive.
Software says a tape is loaded
and drive is in use. But no tape
is in the drive.
•
Popped leader
Operating system reports tape
in the drive. It may or may not
give a bar code. Customers
verify that the drive is empty.
This is a buffer hang condition. The hardware and
software are out of sync.
•
Re-IPL the drive. Try again.
•
Re-IPL the library. Unload all drives from the operating
systems first. Try again.
•
Restart application. Try again.
•
Re-IPL the host
Customer reports drive keeps
going down.
Watch the amount of time it takes the software to down
the drive.
-
If it is a short time it is an operating system
problem.
-
If it is a very long time it can be a drive mapping
problem
•
Bad drive
•
Control path has a problem
Customer reports that he sees 7
or 15 drives on a bus. But there
is only one drive.
•
Wrong address. You have set the drive address to the
same as the host bus adapter (HBA).
This is usually ID 7.
Problem
Possible Causes
Содержание L180
Страница 1: ...L180 Tape Library Service Manual Document 95897...
Страница 2: ......
Страница 3: ...L180 Tape Library Service Manual...
Страница 6: ...Summary of Changes iv Fifth Edition 95897 This page intentionally left blank...
Страница 16: ...Tables xiv Fifth Edition 95897 This page intentionally left blank...
Страница 44: ...Component Overview 1 12 Fifth Edition 95897 This page intentionally left blank...
Страница 68: ...Configuration Overview 2 24 Fifth Edition 95897 This page intentionally left blank...
Страница 254: ...Specifications A 28 Fifth Edition 95897 This page intentionally left blank...
Страница 262: ...Index Index 8 Fifth Edition 95897 This page intentionally left blank...
Страница 265: ......