ST10 FAMILY PROGRAMMING MANUAL
111/172
SCXT
Switch Context
Syntax
SCXT op1,
op2
Operation
(tmp1)
<-- (op1)
(tmp2)
<--(op2)
(SP)
<-- (SP) - 2
((SP)) <--
(tmp1)
(op1) <--
(tmp2)
Data Types
WORD
Description
Used to switch contexts for any register. Switching context is a push and load operation. The contents of
the register specified by the first operand, op1, are pushed onto the stack. That register is then loaded
with the value specified by the second operand, op2.
Flags
Addressing Modes
E
Z
V
C
N
-
-
-
-
-
E
Not affected
Z
Not affected
V
Not affected
C
Not affected
N
Not affected
Mnemonic
Format
Bytes
SCXT
reg, #data
16
C6 RR ## ##
4
SCXT
reg, mem
D6 RR MM MM
4