ST10 FAMILY PROGRAMMING MANUAL
44/172
ANDB
Logical AND
Syntax
ANDB op1,
op2
Operation (op1)
<-- (op1) ^ (op2)
Data Types
BYTE
Description
Performs a bitwise logical AND of the source operand specified by op2 and the destination operand spec-
ified by op1. The result is then stored in op1.
Flags
Addressing Modes
E
Z
V
C
N
*
*
0
0
*
E
Set if the value of op2 represents the lowest possible negative number. Cleared otherwise.
Used to signal the end of a table.
Z
Set if result equals zero. Cleared otherwise.
V
Always cleared.
C
Always cleared.
N
Set if the most significant bit of the result is set. Cleared otherwise.
Mnemonic
Format
Bytes
ANDB
Rb
n
, Rb
m
61 nm
2
ANDB
Rb
n
, [Rw
i
]
69 n:10ii
2
ANDB
Rb
n
, [Rw
i
+]
69 n:11ii
2
ANDB
Rb
n
, #data
3
69 n:0###
2
ANDB
reg, #data
16
67 RR ## ##
4
ANDB
reg, mem
63 RR MM MM
4
ANDB
mem, reg
65 RR MM MM
4