4-6
Keyset Self Test
Chapter 4 - Maintenance and Troubleshooting
STARPLUS STSe - Installation Manual
August 2005
Key Telephones/Terminals
The following actions apply to multi-line key telephones:
Single Line Telephones
The following applies to all 2500-type single line telephones connected to the system.
Table 4-2: Key Telephones/Terminals
Symptom
Action
No power to keyset
Verify that keyset is connected to correct
type of station card.
No handsfree answer-back on intercom
On digital keysets, the mode of intercom
answer is programmable.
CO line/station button will not access
CO line/station
Check flexible button programming for
that button.
Speakerphone does not work
Check station programming for
speakerphone enable.
Cannot call another intercom station
Check off hook preference programming.
No Camp On signals or override to
phone
Check station programming for override
enable.
Table 4-3: Single Line Telephone
Symptom
Action
Phone will not dial out
Verify correct SLT type programmed in
station identification. Verify line group
access programming.
No ringing to phone
Check CO line ringing assignments in
programming.
Message waiting lamp does not work
Check station ID assignment in
programming.
Make sure the MSGU is installed on the
SLIB.
Cannot call another intercom station
Check off hook preference programming.
Put all unused CO lines in a CO line group
not currently being used.
Содержание STSe Key System
Страница 1: ...August 2005 Issue 1 0 STARPLUS STSe Key Systems Installation Manual TM...
Страница 4: ......
Страница 10: ...vi Figures STARPLUS STSe Installation Manual August 2005...
Страница 12: ...viii Tables STARPLUS STSe Installation Manual August 2005...
Страница 14: ...N O T E S...
Страница 22: ...N O T E S...
Страница 30: ...N O T E S...
Страница 68: ...3 40 Door Box Chapter 3 Installation STARPLUS STSe Installation Manual August 2005...
Страница 70: ...N O T E S...
Страница 94: ...iv Index STARPLUS STSe Installation Manual August 2005...