-30-
Installation: Detailed Programming
Slide Switch Programming
The default setting for the Progressive Enable DIP switch is for
“progressive”
switching
(see
DIP Switch Settings on page 6)
. This means that each position will add another function
while keeping the previous one(s) on. Position
1
1
1
1
activates the first function. Position
2
2
2
2
activates the functions connected to both
1
1
1
1
and
2
2
2
2
. Position
3
3
3
3
will activate all of the
functions connected to
1
1
1
1
,
2
2
2
2
, and
3
3
3
3
.
To modify the functions that are activated by each slide
switch position, ensue that control head DIP switch 7 up,
as described on page 6.
When DIP switch 7 is up, the slide switch will operate
based upon the settings you have programmed. By
default the Programmable setting is for NO additional
functions to be activated in each slide switch position
(thus defaulting as Non-Progressive). To change the
settings, proceed below:
Program each Slide Switch position individually.
Verify the Programming DIP switch is UP.
Place the Slide Switch in the position you wish to program.
Activate the HF button.
Modify any buttons that you want to auto-activate for each slide switch position.
If button is
Green
:
(Default setting for all buttons)
This function
WILL NOT activate in the corresponding slide
switch position.
If button
PB1-PB5
,
PB13
, or
PB14
is
Red
: The function attached to each corresponding
output WILL activate when the slide switch is in
the position you are programming.
While Programming For This Slide Switch Position…
1
1
1
1
2
2
2
2
3
3
3
3
MAN
Output
3
3
3
3
will activate when SS in
1
1
1
1
Output
3
3
3
3
will activate when SS in
2
2
2
2
Output
2
2
2
2
will activate when SS in
3
3
3
3
HORN
Output
2
2
2
2
will activate when SS in
1
1
1
1
Output
1
1
1
1
will activate when SS in
2
2
2
2
Output
1
1
1
1
will activate when SS in
3
3
3
3
If This
Button
Is Red...
Slide Switch Outputs Represented By MAN and HORN Buttons
Once you have programmed all necessary options,
you must
flip
the Programming Mode DIP switch down to save the changes.
Slide Switch Programming
P
R
O
G
R
E
S
S
IV
E
E
N
A
B
L
E
Progressive SS
Non-Progressive SS
or Programmable SS
Non-Progressive SS
or Programmable SS
Progressive SS
P
R
O
G
R
E
S
S
IV
E
E
N
A
B
L
E
7
7
To Program Settings for Each
of These Slide Switch Positions:
1
1
1
1
2
2
2
2
3
3
3
3
Programming Mode DIP Switch:
Up
Up
Up
Slide Switch:
1
1
1
1
2
2
2
2
3
3
3
3
Activate this button (RED):
HF
HF
HF
And modify any of these buttons:
PB1-PB5, PB13, PB14, MAN, HORN
All of the options on pages 17
All of the options on pages 17
All of the options on pages 17
All of the options on pages 17----34 can optionally be programmed using free software and a
34 can optionally be programmed using free software and a
34 can optionally be programmed using free software and a
34 can optionally be programmed using free software and a
USB to serial cable (P/N SUSB
USB to serial cable (P/N SUSB
USB to serial cable (P/N SUSB
USB to serial cable (P/N SUSB----850MG) available upon request from StarSignal at 585
850MG) available upon request from StarSignal at 585
850MG) available upon request from StarSignal at 585
850MG) available upon request from StarSignal at 585----226
226
226
226----9787.
9787.
9787.
9787.
Содержание LCS850MG
Страница 1: ...LCS850MG SIREN AMPLIFIER LIGHT CONTROLLER PLIT426 REV G 7 26 18 INSTALLATION AND INSTRUCTION MANUAL...
Страница 31: ......
Страница 32: ...QUICK INSTALLATION GUIDE REMOVABLE CENTERFOLD...
Страница 34: ......
Страница 63: ......
Страница 64: ......