Traffic Directors with Built In Controllers
(Logic Controlled)
The LCS850MG has three different “logic controlled” modes that can be used, depending
upon the input requirements of your Traffic Director. These are as follows:
DL15-30W Configuration:
Stick operated with 4 wires (Warn/Power, Left, Right, and C/O)
Left Arrow activated by power to Warn+Left wires from stick
Right Arrow activated by power to Warn+Right wires from stick
C/O activated by power to Warn+C/O wires from stick
WARN pattern activated by Warn/Power wire
Alt. TD Configuration #1:
Stick operated with 3 wires (Warn, Left, and Right)
Warn, Left, and Right each operate independently
C/O activated by power to only Left+Right wires from stick
Alt. TD Configuration #2:
Stick operated with 3 wires (Center-Out, Left, and Right)
C/O, Left, and Right each operate independently
No Warn Pattern
Installation
Traffic Director Settings: Traffic Directors with Built-In Controllers
This section only applies to those Traffic Directors that have a built-in controller,
but will be operated with the
TD CYCLE
button through “signal” wires.
T
D
M
O
D
E
Using
Traffic Director
3
Not Using
Traffic Director
T
D
O
U
T
P
U
T
Use Built-In 8-Output
Siren TD Controller
Use 3 or 4 Output Signal for
TD w/Internal Controller
(Logic Controlled)
8
P
O
W
E
R
/C
E
N
T
E
R
-O
U
T
L
E
F
T
R
IG
H
T
W
A
R
N
L
E
F
T
R
IG
H
T
P
O
W
E
R
/W
A
R
N
(R
e
d
)
R
IG
H
T
(G
re
e
n
)
C
E
N
T
E
R
-O
U
T
(
P
u
rp
le
)
L
E
F
T
(Y
e
ll
o
w
)
CENTER-OUT= LEFT+RIGHT
LEFT=
RIGHT=
CENTER-OUT=
LEFT+POWER/WARN
RIGHT+POWER/WARN
CENTER-OUT+POWER/WARN
LEFT=
RIGHT=
-
LEFT+POWER/CENTER-OUT
RIGHT+POWER/CENTER-OUT
NO WARN
DEFAULT
FOR EITHER OF THESE LOGIC
OUTPUTS, YOU MUST CHANGE
THE TD SETTINGS!!
(SEE PAGE 32)
!
!
G
R
O
U
N
D
-O
p
ti
o
n
a
l
(B
la
c
k
)
3-WIRE LOGIC + POWER
(DL15-30W)
2-WIRE LOGIC + POWER
(Alt. TD Configuration #2)
3-WIRE INDEPENDENT LOGIC
(Alt. TD Configuration #1)
If you will be using the
TD CYCLE
button on the
LCS850MG control head to operate your “logic
controlled” traffic director i.e. its own internal
controller), please verify that DIP switches 3 and 8 on
the back of the control head are set properly.
(See
pages 5 & 7)
Review the appropriate diagram
above and connect the necessary
wires from your traffic director
harness to the corresponding
terminals on the 12-terminal
connector that plugs into the back
of the LCS850MG-AMP box.
See page 32 to program
the siren for each of the
appropriate
configurations described
above.
Содержание LCS850MG
Страница 1: ...LCS850MG SIREN AMPLIFIER LIGHT CONTROLLER PLIT426 REV G 7 26 18 INSTALLATION AND INSTRUCTION MANUAL...
Страница 31: ......
Страница 32: ...QUICK INSTALLATION GUIDE REMOVABLE CENTERFOLD...
Страница 34: ......
Страница 63: ......
Страница 64: ......