Appendix A – Trouble Shooting
Problem
Possible fault
Possible solution
Lift will not ascend
•
Circuit breaker tripped
•
Isolation keyswitch
turned off
•
Door not locked
•
Carriage safety edge
operated/sticking.
Platform safety edge
operated/sticking.
Mains switch turned
off. Motor overload
tripped in pump unit.
Platform overloaded
(indicator on carriage).
Shut off valve closed.
Pump running but will
not raise lift
•
Reset. Turn on (3
switches)
•
Ensure door is closed
and locks fully
engaged. Remove
obstruction
•
Remove obstruction
•
Turn on. Reset
•
Remove excess load
•
Open valve. Pressure
relief valve open.
Check platform load.
Adjust valve if
required. Down
solenoid valve stuck
open - dirt in the
system
Lift will not descend
•
Door open
•
Ultimate limit operated
•
Platform overloaded
(indicator on carriage).
Down solenoid valve
not operational.
Rupture valve (base of
ram) activated
•
Close door. Lower lift
by manual operation
and reset switch.
Remove excess load
•
No 24V power to valve
•
Check system is
working correctly and
raise lift to release
rupture valve
Lift stops below upper floor
level
•
Up stopping switch
activated
•
Journey timer tripped
•
Adjust as required
•
Reset and adjust if
necessary
Lift stops above lower floor
level
•
Down stopping switch
activated
•
Adjust as required
Door will not open
•
Lift not in door zone.
Door zone switch not
activated
•
Call lift to floor level.
Adjust as required.
Lift sinks away from top floor
over time
•
Anti-creep not
operating correctly
•
Adjust anti-creep
switch as required