To start the tool, slide the slider switch 1 toward the front of
the tool and press, the tool will keep running. Release
pressure from the switch and the tool will stop.
Lock feature of the ON/OFF switch
Slide slider switch 1 to the front of the tool and press, and
the tool will start. When releasing the switch, keep the
switch pressed down and push it to the front of the tool, and
the tool will keep running. To turn off the tool, press the front
portion of the switch to release it. The switch will spring up,
which means that the tool is in the off-state.
Explanation: Before coming into contact with the object you
are working on, make sure the abrasive wheel is turning at
maximum speed. Before turning off the tool, lift the tool up
from the object you are working on.
Caution:
Make sure the abrasive wheel is
completely stopped before putting down the tool.
Rotating the Gear Case (fig. E)
The gear case is mounted onto the tool casing, and it can
be rotated to give the user a more comfortable experience
while cutting.
The rotating gear case can be turned 90 degrees, 180
degrees, and 270 degrees to the left or to the right.
• Loosen the four screws on the gear case.
• Rotate the gear case till it reaches its ideal location.
• Tighten the four screws on the gear case.
• Ensure that the rotating mechanism is locked.
Warning
: Do NOT use the tool when the gear case
is unlocked.
Application on Metals
When applying the tool on metals, make sure that a
residual-current device (RCD) is inserted to prevent danger
from metal chips.
If the RCD causes power disconnection, have the tool sent
to an authorized STANLEY dealer for repair.
Warning
: Under extreme working conditions,
conductive dust and grit may accumulate on the
housing interior when handling metal workpieces. This could
create an electric shock hazard as it weakens the protective
insulation in the grinder.
To avoid accumulation of metal chips in the interior of the
grinder, we recommend cleaning the ventilation ducts daily.
Refer to Maintenance.
Using Grinding Wheels
Warning: Metal powder accumulates.
Excessive
use of the grinding wheel on metals may increase
the risk of electric shock. To reduce the risk, insert
the RCD before use and clean the ventilation ducts daily.
Follow the maintenance instructions below to blow dry
compressed air into the ventilation ducts.
Maintenance
STANLEY power tools have been designed to operate over
a long period of time with minimal maintenance. Continuous
satisfactory operation depends upon proper tool care and
regular cleaning.
Warning: To minimize the danger of serious
personal injury, please switch off the tool power
and disconnect all plugs before adjusting or
removing/installing any accessory.
Before reassembling
the tool, press and release the trigger switch to make sure
the tool is already switched off.
Lubrication
This power tool does not require separate lubrication.
Cleaning
Warning
: Once visible dust accumulates on the
ventilation ducts and the surrounding, immediately
use dry air to blow away dust and grit out of the interior of
the housing. You need to wear approved eye and facial
protective gear when performing this process.
Warning
: Never use solvents or harsh chemicals to
clean non-metal parts of the tool. These chemicals
may weaken the material of the parts. Use only mild soap
and damp cloth to clean the tool. Never let any liquid get
inside the tool; never immerse any part of the tool into liquid.
11
ENGLISH
(Original instructions)
Содержание STGL2223
Страница 1: ...STGL2223 English Page 3 Russian Page 17 Ukrainian Page 30...
Страница 2: ...ENGLISH 2 Original instructions A C1 B 4 3 1 2 20 3 6 7 5...
Страница 3: ...3 ENGLISH Original instructions C2 C3 E D 10 8 9 7 6 3 10 8 6 7 10 8 6 7 4 10 10 11 90o...
Страница 4: ...ENGLISH 4 Original instructions F G 15o 30o A B...
Страница 14: ...14 A C1 B 4 3 1 2 20 3 6 7 5...
Страница 15: ...15 C2 C3 E D 10 8 9 7 6 3 10 8 6 7 10 8 6 7 4 10 10 11 90o...
Страница 16: ...16 F G 15o 30o A B...
Страница 17: ...17 1 b 2 b d STGL2223 W 2200 V 220 240 Hz 50 60 1 6500 speed 230 6 6 27 M14 6...
Страница 18: ...18 f 3 a b d f g 4 a b c d c f g 5...
Страница 19: ...b c d e f g h i j k l m n 19...
Страница 20: ...20 o p a b c d a b c d e...
Страница 21: ...21 1 1 1 1 1 1 1 1 2 3 Stanley STANLEY 3 1 5 2 30 A n0 2014 XX JN II...
Страница 23: ...G G 1 23 1 1 E 90 180 270...
Страница 24: ...24 STANLEY STANLEY STANLEY STANLEY STANLEY STANLEY...
Страница 26: ...26 1 STANLEY 2 3 24 5 4 STANLEY www 2helpU com 5 6 7 7 1 7 2 7 3 7 4 7 5 8 8 1 8 2 8 3 8 4 65510 40...
Страница 27: ...27 A C1 B 4 3 1 2 20 3 6 7 5...
Страница 28: ...28 C2 C3 E D 10 8 9 7 6 3 10 8 6 7 10 8 6 7 4 10 10 11 90o...
Страница 29: ...29 F G 15o 30o A B...
Страница 30: ...30 STGL2223 W 2200 V 220 240 Hz 50 60 1 6500 230 6 6 27 M14 6 1 b 2 b d f...
Страница 31: ...31 3 a b d f g 4 a b c d f g 5...
Страница 32: ...32 b c d e f g h i j k l m n o p...
Страница 33: ...33 a b c d e a b c d e 1 1 1 A n0 2014 XX JN II...
Страница 34: ...34 1 1 1 1 1 2 3 Stanley Stanley 3 1 5 2 30 B 1 2 11 3 4 150 4 20 1 20 2 3 C1 C2 C3 1 2 6 7 1 3 8 6 2 9 6...
Страница 35: ...35 4 10 7 3 10 10 5 2 7 2 6 10 7 8 10 D 4 11 12 F 1 2 15 30 3 B G G...
Страница 36: ...36 1 1 1 E 90 180 270 STANLEY STANLEY...
Страница 37: ...37 STANLEY STANLEY STANLEY STANLEY Stanley Stanley Stanley Stanley Stanley www 2helpu com10...