36 Programming Commands
SR620 Universal Time Interval Counter
j scale
0
histogram
vertical
1
histogram
horizontal
2
histogram
bins
3
mean
vertical
4
jitter
vertical
The parameter x is the desired units/division
(example: for 100ns/div x = 100E-9). The scale
values are all positive numbers except that a
negative value for the histogram vertical scale will
set the scale to log mode. An error will occur if an
attempt is made to set the scale to an illegal value.
This can happen, for example, for certain
combinations of histogram horizontal scales and
bin sizes.
PDEV (?) j
The PDEV command sets the hardcopy output
device. The parameter j = 0 set the device to
printer while j = 1 sets it to plotter.
PLAD (?) j
The PLAD command sets the address of the GPIB
plotter if a plotter is being used. Any address
from 0 to 30 except the current address of the
SR620 may be used.
PLPT (?) j
The PLPT command sets the plotter output port to
either RS232 or GPIB. The parameter j = 0 set
the port to RS232 while j = 1 sets the port to GPIB.
PLOT
The PLOT command starts a plot or print.
PCLR
The PCLR command clears any plots or prints in
progress.
Front Panel Control
KEYS(?) j
The KEYS command simulates the pressing of a
front panel key. The KEYS? query returns the
keycode of the most recently pressed key.
Keycodes are assigned as follows:
Key
keycode
mode
up
16
mode
down
17
source
18
size
up
25
size
down
27
measurement
start
32
measurement
reset
34
display
up
33
display
down
35
set
rel
40
clear
rel
42
set
graph
43
autoscale
41
display
scales
22
scale
up
20
scale
down
23
21
clear
29
config
select
28
config
set
30
Ext
slope
36
Manual
Trigger
31
Ext
termination
39
A
slope
37
A
ac/dc
38
A
termination
47
B
slope
44
B
ac/dc
46
B
termination
45
ref
level
19
set
auto
measure
50
set
autoprint
51
clear
automeasure
52
clear
autoprint
53
Содержание SR620
Страница 2: ...SR620 Universal Time Interval Counter...
Страница 6: ...iv Table of Contents SR620 Universal Time Interval Counter...
Страница 8: ...vi Safety and Preparation for Use SR620 Universal Time Interval Counter...
Страница 12: ...x Specifications SR620 Universal Time Interval Counter...
Страница 58: ...42 Programming Commands SR620 Universal Time Interval Counter...
Страница 72: ...56 Programming Examples SR620 Universal Time Interval Counter...
Страница 76: ...60 Troubleshooting Tips SR620 Universal Time Interval Counter...
Страница 82: ...66 Performance Test SR620 Universal Time Interval Counter...
Страница 90: ...74 Calibration Procedure SR620 Universal Time Interval Counter...
Страница 102: ...86 Circuit Description SR620 Universal Time Interval Counter...
Страница 124: ...108 Parts List SR620 Universal Time Interval Counter...