100
left of the printing area, the horizontal motion unit (x) is used.
The horizontal and vertical motion unit are specified by
GS
P
.
The
GS P
command can change the horizontal (and
vertical) motion unit. However, the value cannot be less than
the minimum horizontal movement amount, and it must be in
even units of the minimum horizontal movement amount.
[Reference]
ESC $
,
ESC T
,
ESC W
,
ESC \
,
GS $
,
GS P
GS ^ r t m
[Name] Execute macro
[Format] ASCII GS ^ r t m
Hex 1D 5E r t m
Decimal 29 94 r t m
[Range] 0
r
255; 0
t
255;m
0, 1
[Description] Executes a macro.
r specifies the number of times to execute the macro.
t specifies the waiting time for executing the mac
ro.
m specifies macro executing mode.
When the LSB of m = 0:
The macro executes r times continuously at the interval
specified by t.
When the LSB of m = 1:
After waiting for the period specified by t, the PAPER OUT
LED indicators blink and the printer waits for the FEED button
to be pressed. After the button is pressed, the printer
Содержание SP-T8
Страница 1: ...1 R SPRT SP T8 Portable Thermal Printer User s Manual...
Страница 6: ...6 FS S n1 n2 122 FS W n 124...
Страница 27: ...27 Bit 5 Becomes on when the paper end sensor detects paper end and printing stops n 3 Error status...
Страница 40: ...40 When font B 9 17 is selected...
Страница 77: ...77 performed by the FS p command Reference FS p Example When xL 64 xH 0 yL 96 yH 0...