61
starting position and printing area width, and use the vertical
motion unit ( y) for setting the vertical starting position and
printing area height.
When the horizontal starting positio
n , vertical starting
position, printing area width, and printing area height are
defined as X, Y, Dx, and Dy respectively, the printing area is
set as shown in the figure below.
This printable area for this printer is approximately 72.2
mm (512/180 inches) (for 58 mm paper width mode; 50.8 mm
(360/180 inches)) in the horizontal direction and
approximately 117.3 mm (1662/360 inches) in the vertical
direction.
[Default] xL = xH = yL = yH = 0
dxL = 0, dxH = 2, dyL = 126, dyH = 6
Содержание SP-T8
Страница 1: ...1 R SPRT SP T8 Portable Thermal Printer User s Manual...
Страница 6: ...6 FS S n1 n2 122 FS W n 124...
Страница 27: ...27 Bit 5 Becomes on when the paper end sensor detects paper end and printing stops n 3 Error status...
Страница 40: ...40 When font B 9 17 is selected...
Страница 77: ...77 performed by the FS p command Reference FS p Example When xL 64 xH 0 yL 96 yH 0...
Страница 78: ...78...