69
This document is written and published by ShockWatch, Inc. All rights reserved.
USER MANUAL
The Rectangular (Boxcar) is the equivalent of having no windowing. The Hanning window is a common windowing
tool. The various window tools allow the user to address the beginning and ending of an impact event which by its
nature is not a continuous signal.
The Report Graph View sets the scales (linear or logarithmic) of the FFT graph.
Scroll through the events until the event of interest is displayed. Turn the FFT or PSD analysis on by clicking FFT/
PST Off and selecting the desired graph view. FFT Lin/Lin was selected for the image below: