103
APPENDIX B - SHOCKLOG CELLULAR
This document is written and published by ShockWatch, Inc. All rights reserved.
DESCRIPTION & FEATURES
POWERING THE SHOCKLOG CELLULAR
MODULE
CONNECTING THE SHOCKLOG
CELLULAR MODULE
The ShockLog Cellular Impact Recording & Tracking System combines the ShockLog 298 impact recorder and a
cellular communication module to deliver impact recording, real-time reporting of event/alarm conditions and
asset location.
The ShockLog Cellular Module may be used with any ShockLog 298 Impact Recorder with firmware revision 30
or greater.
All the required lithium batteries for the ShockLog Cellular are provided unless otherwise arranged with SpotSee.
To install the batteries, please follow the instructions below:
Unscrew the Battery Panel (see image to the right).
Note: A Phillips screwdriver is required to complete this step.
Install the six (6) AA batteries provided in the direction noted in each
battery slot, verify that the gasket is in place and replace the battery
panel making sure that the certification label is visible. Tighten the
screws on the battery panel to preserve IP 67 rating.
The ShockLog Cellular module and the ShockLog 298 must be
connected prior to use. Attach the Hirschman connector on
the cellular module to the Hirschman plug on the ShockLog 298.