Remove the Eight-Drive Backplane
c.
Extend the server into the service position.
See
“Extend the Server to the Service Position” on page 55
d.
Remove the fan cover.
Remove the 12 fan cover screws, then slide the cover forward and lift it off the server.
e.
If necessary, remove the fan modules from the server.
See
“Remove a Fan Module” on page 79
.
2.
Pull each drive out far enough to disengage it from the drive backplane.
Note -
You do not need to completely remove the storage drives from the server. Simply
pull them out far enough to disengage them from the drive backplane. If you do remove the
storage drives from the server, record their locations so that you can reinstall them in the same
locations.
3.
Disconnect the cables from the drive backplane.
a.
Disconnect the two SAS cables from the drive backplane that go to the card
in internal SAS slot 7 (panel 1).
132
SPARC S7-2L Server Service Manual • March 2017
Содержание S7-2L
Страница 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Страница 2: ......
Страница 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Страница 25: ...Device Paths Internal Component Locations on page 20 Device Paths on page 23 Identifying Components 25...
Страница 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Страница 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Страница 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Страница 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Страница 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Страница 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Страница 92: ...Verify a Power Supply Rear Panel Components on page 19 92 SPARC S7 2L Server Service Manual March 2017...
Страница 156: ...156 SPARC S7 2L Server Service Manual March 2017...