Remove the Twelve-Drive NVMe Backplane
2.
Pull each drive and filler out far enough to disengage it from the drive backplane.
Note -
You do not need to completely remove the storage drives from the server. Simply
pull them out far enough to disengage them from the drive backplane. If you do remove the
storage drives from the server, record their locations so that you can reinstall them in the same
locations.
3.
Disconnect the cables from the drive backplane.
a.
Disconnect the two power cables from the drive backplane.
b.
Disconnect the 12 NVMe cables from the drive backplane.
c.
Disconnect the auxiliary signal cable from the drive backplane.
140
SPARC S7-2L Server Service Manual • March 2017