Remove a Drive or Drive Filler
4.
If you are hot-servicing the drive, locate the drive that displays the amber Fault
LED and ensure that the blue Ready to Remove LED is lit.
5.
If you are cold-servicing the drive, power off the server. Complete one of the
“Removing Power From the Server” on page 50
6.
Attach an antistatic wrist strap.
7.
On the drive or drive filler you want to remove, complete the following tasks.
Caution -
The latch is not an ejector. Do not bend it too far to the right. Doing so can damage
the latch.
a.
Push the release button to open the latch.
b.
Unlock the drive by moving the latch to the right.
70
SPARC S7-2L Server Service Manual • March 2017