Performing Advanced Troubleshooting
No.
LED
Icon or Label
Description
4
Service Required LED
(amber)
The
fmadm
faulty
command provides details about any
faults that cause this indicator to light. See
Under some fault conditions, individual component fault LEDs are lit
in addition to the Service Required LED.
5
Power OK LED (green)
Indicates these conditions:
■
Off
– Server is not running in its normal state. Server power might
be off. The SP might be running.
■
Steady on
– Server is powered on and is running in its normal
operating state. No service actions are required.
■
Fast blink
– Server is running in standby mode and can be quickly
returned to full function.
■
Slow blink
– A normal but transitory activity is taking place. Slow
blinking might indicate that system diagnostics are running or that
the system is booting.
6
Host Ethernet Port Link/
Activity LED (green)
From left to right, NET 1,
NET 0, NET 3, and NET 2.
Indicates these conditions:
■
Off
– No link is established.
■
Steady On
– A link is established.
■
Blinking
– A link is established, and there is activity on the port.
7
NET MGT Port Link and
Activity LED (green on left)
NET MGT Port Speed LED
(green on right)
LINK/ACT
SPD
Indicates these conditions:
■
Off
– No link is established.
■
Steady On
– A link is established.
■
Blinking
– A link is established and there is activity on the port.
Indicates these conditions:
■
Off
– The link is operating as a 10 Mbps connection.
■
Steady On
– The link is operating as a 100 Mbps connection.
Related Information
■
“Front Panel Controls and LEDs” on page 34
■
“Checking for Faults” on page 27
Performing Advanced Troubleshooting
If you are unable to diagnose faults using the methods provided in
, use any of the following methods to diagnose faults on the server.
36
SPARC S7-2L Server Service Manual • March 2017
Содержание S7-2L
Страница 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Страница 2: ......
Страница 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Страница 25: ...Device Paths Internal Component Locations on page 20 Device Paths on page 23 Identifying Components 25...
Страница 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Страница 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Страница 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Страница 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Страница 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Страница 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Страница 92: ...Verify a Power Supply Rear Panel Components on page 19 92 SPARC S7 2L Server Service Manual March 2017...
Страница 156: ...156 SPARC S7 2L Server Service Manual March 2017...