Enable and Verify a DIMM
c.
Gently press the DIMM into the slot until the ejector tabs lock the DIMM in
place.
Repeat these steps until each DIMM has been installed.
4.
Return the server to operation.
a.
Install the top cover.
See
“Replace the Top Cover” on page 152
.
b.
Return the server to the normal operating position.
See
“Return the Server to the Normal Operating Position” on page 153
.
c.
Reinstall the power cords to the power supplies and power on the server.
See
“Returning the Server to Operation” on page 149
Related Information
■
“DIMM Configuration” on page 93
■
■
“Enable and Verify a DIMM” on page 100
Enable and Verify a DIMM
1.
Access the Oracle ILOM prompt.
2.
Use the
show faulty
command to determine how to clear the fault.
■
If the output indicates a POST-detected fault, go to
■
If the output displays a UUID, which indicates a host-detected fault, go to
.
3.
Use the
set
command to enable the DIMM that was disabled by POST.
In most cases, replacement of a faulty DIMM is detected when the service processor is power
cycled. In those cases, the fault is automatically cleared from the server. If
show faulty
still
displays the fault, the
set
command will clear it.
->
set /SYS/MB/CMP1/MCU0/CH1/D0 requested_config_state=Enabled
100
SPARC S7-2L Server Service Manual • March 2017
Содержание S7-2L
Страница 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Страница 2: ......
Страница 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Страница 25: ...Device Paths Internal Component Locations on page 20 Device Paths on page 23 Identifying Components 25...
Страница 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Страница 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Страница 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Страница 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Страница 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Страница 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Страница 92: ...Verify a Power Supply Rear Panel Components on page 19 92 SPARC S7 2L Server Service Manual March 2017...
Страница 156: ...156 SPARC S7 2L Server Service Manual March 2017...