Install the Twelve-Drive Backplane
4.
Using a No. 2 Phillips screwdriver, loosen the captive screw that secure the drive
backplane to the disk cage.
5.
Lift the drive backplane and attached SAS expander, over the nine hooks that
secure it, then lift the assembly up and out of the chassis.
6.
Place the drive backplane on an antistatic mat.
Install the Twelve-Drive Backplane
1.
Lower the drive backplane into the server, position it in front of the standoff
hooks, then push the backplane into place.
The standoff hooks fit into small openings in the drive backplane. Ensure that all cables are out
of the way.
2.
Using a No. 2 Phillips screwdriver, tighten the captive screw to secure the drive
backplane to the disk cage.
3.
Reconnect the cables to the drive backplane.
a.
Reconnect the auxiliary signal cable to the drive backplane.
b.
Reconnect the power cable to the drive backplane.
c.
Connect the three SAS cables to the SAS expander.
Attach cables to the similarly-labeled connectors.
4.
Return the server to operation.
a.
Install the fan modules.
See
“Install a Fan Module” on page 82
b.
Install the fan cover, and close the fan door.
Replace the fan cover and secure it with the two side screws and three top screws.
c.
Fully install all storage drives you disengaged or removed.
See
“Install a Drive or Drive Filler” on page 72
.
d.
Return the server to the normal operating position.
138
SPARC S7-2L Server Service Manual • March 2017
Содержание S7-2L
Страница 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Страница 2: ......
Страница 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Страница 25: ...Device Paths Internal Component Locations on page 20 Device Paths on page 23 Identifying Components 25...
Страница 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Страница 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Страница 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Страница 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Страница 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Страница 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Страница 92: ...Verify a Power Supply Rear Panel Components on page 19 92 SPARC S7 2L Server Service Manual March 2017...
Страница 156: ...156 SPARC S7 2L Server Service Manual March 2017...