Install a Fan Module
4.
Install the replacement fan module into the server by completing the following
tasks.
a.
Align the fan module and slide it into the fan slot (panel 1).
Note -
Fan modules are keyed to ensure that they are installed in the correct orientation.
Ensure that the cables threaded between the two middle fan modules are not caught.
b.
Apply firm pressure to fully seat the fan module.
You will hear a click when the fan module is properly seated.
c.
Tighten the green screw to hold the fan module in place (panel 2).
Servicing Fan Modules
83