Enable and Verify a DIMM
4.
For a host-detected fault, perform the following steps to verify the new DIMM.
a.
Set the virtual keyswitch to
diag
so that POST runs in Service mode.
->
set /HOST keyswitch_state=Diag
Set 'keyswitch_state' to 'Diag'
b.
Power cycle the server.
->
stop /System
Are you sure you want to stop /System (y/n)?
y
Stopping /System
->
start /System
Are you sure you want to start /System (y/n)?
y
Starting /System
c.
Check if the host has been powered off.
Allow approximately one minute before performing this step. Type the
show /HOST
command. When the host is powered off, the console displays
status=Powered Off
.
d.
Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output indicates that
POST did not detect any faults:
->
start /HOST/console
...
0:0:0>INFO:
0:0:0> POST Passed all devices.
0:0:0>POST: Return to VBSC.
0:0:0>Master set ACK for vbsc runpost command and spin...
Note -
The server might boot automatically at this point. If so, go directly to
. If the
server remains at the OpenBoot prompt (
ok
) go to the next step.
e.
If the server remains at the OpenBoot prompt, type
boot
.
f.
Return the virtual keyswitch to Normal mode.
->
set /HOST keyswitch_state=Normal
Set 'keyswitch_state' to 'Normal'
g.
Switch to the system console and type the Oracle Solaris
fmadm faulty
command.
Servicing DIMMs
101
Содержание S7-2L
Страница 1: ...SPARC S7 2L Server Service Manual Part No E73201 04 March 2017...
Страница 2: ......
Страница 10: ...10 SPARC S7 2L Server Service Manual March 2017...
Страница 25: ...Device Paths Internal Component Locations on page 20 Device Paths on page 23 Identifying Components 25...
Страница 26: ...26 SPARC S7 2L Server Service Manual March 2017...
Страница 44: ...44 SPARC S7 2L Server Service Manual March 2017...
Страница 61: ...Remove the Fan Cover Use a T6 Torx screwdriver Preparing for Service 61...
Страница 64: ...64 SPARC S7 2L Server Service Manual March 2017...
Страница 76: ...76 SPARC S7 2L Server Service Manual March 2017...
Страница 86: ...86 SPARC S7 2L Server Service Manual March 2017...
Страница 92: ...Verify a Power Supply Rear Panel Components on page 19 92 SPARC S7 2L Server Service Manual March 2017...
Страница 156: ...156 SPARC S7 2L Server Service Manual March 2017...