This option value parameter deals with the delay before the initiation of the night park and fire
park functions on the same controller that interfaces to the fire/night box. It is a value expressed
in seconds. In the example above, the special function will begin only after the option jumper
has been closed for two minutes. CAUTION: DO NOT SET THE VALUE TO “0” WITH
MULTIPLE MOTOR CARRIAGES. See page 23 for details regarding entry of a numeric value.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - > O P T I O N V A L U E 1 - A i s l e S p a c i n g
E n t e r V a l u e < 0 - 2 5 5 > - 4 0 _
U s e < > t o S e l e c t O p t i o n
V a l u e < E N T E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Option Value 1 Aisle Spacing Parameter Screen --
This first option value parameter determines the space between carriages when the module initiates
any evenly spacing function. The large check mark to the right indicates that only one controller
needs to be programmed (usually the one that interfaces to the fire/night box or has been configured
for an auto move option, see page 40). The value is a time expressed in tenths of seconds of carriage
travel. The example above will allow the first carriage to move for four seconds before the next
carriage begins to move and another four seconds for the next carriage to move. Press the HELP key
for more information. See page 23 for details regarding entry of a numeric value.
For EC300A systems version 4.6 and earlier use the following equation for a starting point:
Aisle Spacing Parameter = (Aisle Width in inches
÷
Number of Aisles) X 2.9
For EC400 systems and EC300A systems version 4.7 and later use the following equation:
Aisle Spacing Parameter = (Aisle Width in inches
÷
Number of Aisles) X 5.8