DPU/DO - Page 34 - REV. 5/25/00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - > B A Y L I G H T T I M E O U T
( s e c . )
E n t e r V a l u e < 1 - 2 5 5 > - 1 0 _
U s e < > t o S e l e c t O p t i o n
V a l u e < E N T E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Bay Light Timeout Parameter Screen --
This screen is only displayed if bay lighting has been selected (regardless of timed or not timed
parameter selection). When equipped with bay lighting (only the controller that has the bay
lighting control box needs to be set), this parameter specifies the amount of time the bay lights
will remain on after an activation. This value can be set from 1 to 255 seconds (approximately
4.25 minutes maximum). See page 23 for details regarding entry of a numeric value.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > Z E R O F O R C E S E N S O R S
* ( 0 ) N o
( 1 ) Y e s
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Zero Force Sensors Parameter Screen --
This parameter screen allows the user to set the system to be equipped with Zero Force Sensors
(ZFS) by selecting YES. Selecting NO turns off the Zero Force Sensors option. The values
displayed on the diagnostic unit are the parameters as stored in the EC300A/EC400 board, not in
the ZFS board. When the SAVE function is performed all the parameters are sent to and saved
on the EC300A/EC400 board, which then forwards the ZFS parameters to the ZFS controller
board (if its I2C cable is plugged in, from EC300A/EC400-J24 to ZFS-J15). If the ZFS board is
changed or a new I2C chip is installed, it will have to be reprogrammed. The ZFS board will
toggle the right sweep relay after it receives new parameters. Pressing the HELP key at any time
while in the "Set Parameters" section will display this screen. If this screen is set for "No" then
the following seven ZFS screens will not be displayed.