DPU/DO - Page 30 - REV. 5/25/00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - > A U T O S T O P T I M E O U T ( s e c . )
E n t e r V a l u e < 2 0 - 2 5 5 > - 3 0 _
U s e < > t o S e l e c t O p t i o n
V a l u e < E N T E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Auto Stop Timeout Parameter Screen --
This parameter screen allows the user to set the amount of time the motor can continue running
in an effort to complete the movement cycle. After running for the entered amount of time, in
seconds, the motor will shut down. This prevents damage from misadjusted or malfunctioning
limit switches. Any value from 20 to 255 seconds can be entered for this parameter. See page 23
for details regarding entry of a numeric value.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > P O S I T I O N O N C A R R I A G E
* ( 0 ) A l o n e ( 2 ) M i d d l e
( 1 ) F r o n t ( 3 ) R e a r
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Position On Carriage Parameter Screen --
On an EC300A/EC400 system, the same controller board is used in all multiple motor carriage
configurations. If the carriage controller is in a single motor configuration, pick 0 for ALONE.
Select a 1 for FRONT if the carriage controller is the first in line on a multiple motor carriage. If
the carriage controller is neither the first nor last on a multiple motor carriage, choose a 2 for
MIDDLE. If the controller is the last in line on a multiple motor carriage, then select a 3 for
REAR. Remember that the unit number displayed in the upper right hand corner shows the
controller unit in the module, not the carriage number. For example, if there is a three carriage
module with four motors per carriage, units number 9, 10, 11 and 12 would be the front, middle,
middle and rear positions respectively on the third carriage. If this screen is set for Alone, the
next screen will not be displayed. NOTE: It is very important that the A and B hardware
jumpers (JP3 and JP2 respectively) correspond with this parameter for each controller.
Parameter JP3
JP2
Alone
Normal
Normal
Front
A
Normal
Middle
A
B,B
(2
jumpers
required)
Rear
Normal
B,B
(2
jumpers
required)