DPU/DO - Page 47 - REV. 5/25/00
POWER PRO PARAMETER SCREENS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > A I S L E / B A Y L I G H T T I M I N G
* ( 0 ) N o t T i m e d
( 1 ) T i m e d
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Light Timed Parameter Screen --
The aisle light signal is on when the module is finished moving, a safety is activated (photo
sweep, mechanical sweep, aisle entry sensor) or an aisle is locked (when set for manual reset
mode). It turns off when the module is restored to the Ready For Use (all green) state. If the Bay
Lighting option is selected, the signal is turned on in the same manner, however there can be
some delay before the signal turns off. It will turn off when the module is restored to the Ready
For Use state and after the set Bay Light Timeout value has expired when set for timed. When
set for not timed the bay lights will remain on until the user presses the last accessed aisle reset
button and allows the Aisle Relock Timeout to expire. This permits the user to request another
aisle to open without the bay lights turning off and then back on when carriages start to move.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > L I G H T I N G T I M E O U T ( s e c o n d s )
* ( 0 ) S e c o n d s
( 1 ) M i n u t e s
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Light Timeout Units Parameter Screen --
This screen is only displayed if timed lighting has been selected. This screen selects the units of
time for the lights to turn off. This value can be set from 5 to 255 seconds (approximately 4.25
minutes maximum). Or if the minutes choice is selected the value can be set from 5 to 255
minutes (approximately 4.25 hours maximum). See page 23 for details regarding entry of a
numeric value.