DPU/DO - Page 46 - REV. 5/25/00
POWER PRO PARAMETER SCREENS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - > R E L O C K T I M E O U T ( s e c o n d s )
E n t e r V a l u e < 1 0 - 2 5 5 > - 1 0 _
U s e < > t o S e l e c t O p t i o n
V a l u e < E N T E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Aisle Relock Timeout Parameter Screen --
This screen is only shown if the Relock Aisle Mode has been selected. When the system is
configured for manual reset mode, a locked aisle that was cleared will relock after this specified
time. This value can be set from 10 to 255 seconds (approximately 4.25 minutes maximum).
See page 23 for details regarding entry of a numeric value.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > L I G H T I N G C O N T R O L
* ( 0 ) A i s l e
( 1 ) B a y
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Lighting Control Output Parameter Screen --
The same output (J22) on the Power Pro control board can function as the left and right aisle
lighting or as a bay lighting control output. Aisle lights will turn on only when the aisle on either
side of the carriage controller board is open and a lighting request has been made. When the Bay
lighting option is selected, any carriage can generate a signal for bay lights to turn on when a
lighting request has been made. Typically only one controller has a bay lighting interface box.
A lighting request is generated when the module is finished opening the desired aisle, or when a
safety is activated (photo sweep, mechanical sweep, aisle entry sensor) or an aisle is locked
(when set for manual reset mode) or when the move button on the open aisle is pushed again.
To make the bay lighting work with stationary carriages it requires that all controllers are set for
bay lighting even though only one controller needs to have the bay lighting interface control box.