DPU/DO - Page 36 - REV. 5/25/00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > E X C E S S I V E B A C K G R O U N D L I G H T
* ( 0 ) N e i t h e r ( 2 ) L e f t
( 1 ) R i g h t ( 3 ) B o t h
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- ZFS Background Light Parameter Screen --
This screen is only shown if ZFS has been selected. The ZFS controller will normally test for
"no light" seen by the receivers before energizing the transmitter. If there is an exceptional
amount of infrared background light the "no light" test will fail, indicating a bad transmitter and
receiver pair. This parameter allows for the setting of the option to skip the "no light" test.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > Z F S R E S E T W I T H K E Y
* ( 0 ) N o K e y
( 1 ) K e y R e q u i r e d
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- ZFS Reset With Key Parameter Screen --
This screen is only shown if ZFS has been selected. When an aisle locks up it can normally be
reset by pushing the reset button on the control head. The EC300A/EC400 sends the reset
command to the ZFS controller via the I2C cable. When this parameter option is set it requires
that a Program Key (also known as an ON/OFF/STAT/MOVE key) be inserted into the
front
control head of an EC300A of the locked aisle. Then pressing the "ON" key and the reset button
together should clear the aisle. It requires pressing the reset key on the infrared "Managerial
Key" for an EC400 controller system.