DPU/DO - Page 33 - REV. 3/14/2002
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - > A I S L E L I G H T T I M E O U T
E n t e r V a l u e < 6 - 2 5 5 > - 1 0 _
U s e < > t o S e l e c t O p t i o n
V a l u e < E N T E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Aisle Light Timeout Parameter Screen --
This screen is only shown if timed lights have been selected. When a mobile system is equipped
with aisle lighting, and that aisle lighting is set to be timed, this parameter specifies the amount
of time the aisle lights will stay on after an activation. This value can be set from 6 to 255
seconds (approximately 4.25 minutes maximum). See page 23 for details regarding entry of a
numeric value.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > O P T I O N O U T P U T F O R
* ( 0 ) A c c e s s I n d i c a t o r
( 1 ) B a y L i g h t i n g
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Option Output For Parameter Screen --
Attention:
Regarding EC400 logic only, the global “
√
” applies to all other systems. When the
system is equipped with bay lighting, all carriages within the system must have “bay lighting”
selected.
The large check mark indicates that this setting is only required on the controller that interfaces
to the bay lighting control box. There is one option output on the EC300A/EC400 control board
that can function as an access indicator light output or as a bay lighting control output. The
access indicator signal is on when the module is moving, a safety is activated (ZFS, sweep, floor,
etc.) or an aisle is locked (when set for manual reset mode). It turns off when the module is
restored to the Ready For Use (all green) state. If the Bay Lighting option is selected, the signal
is turned on in the same manner, however there can be some delay before the signal turns off. It
will turn off when the module is restored to the Ready For Use state and after the set Bay Light
Timeout value has expired (provided that the timed option is selected, see page 32). When set
for not timed the bay lights will remain on until the user presses the last accessed aisle reset
button and then allows the set Bay Light Timeout to expire (EC400 turns off immediately after
pushing reset). If this screen is set for "Access Indicator" the next screen will not be displayed.