DPU/DO - Page 50 - REV. 5/25/00
POWER PRO PARAMETER SCREENS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > M O V E M E N T M O D E
( 0 ) T o u c h a n d H o l d
* ( 1 ) O n e T o u c h
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Movement Mode Parameter Screen --
The first of these screens deals with the movement mode of the mobile storage system. There are
two choices for this parameter. The first, TOUCH AND HOLD, requires the operator to
continue holding the move button on the face panel control until the movement is complete. The
second, ONE TOUCH, allows the operator to release the move button on the face panel control
and have the module complete the movement cycle on its own. Press the ESCAPE key to return
to the Diagnostic Selection screen. Press the NEXT key to display the next screen shown below.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
* * S e t P a r a m e t e r s F o r U n i t - 1 * *
- - - > L E F T L I M I T S
* ( 0 ) S h a r e
( 1 ) D o n ' t S h a r e
U s e < > t o S e l e c t O p t i o n
U s e < N U M B E R > t o S e t O p t i o n
< S A V E > t o S a v e < E S C A P E > t o E x i t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-- Left Limits Parameter Screen --
This parameter deals with how left limit switches are handled on an individual carriage. If the
carriage does not have its own left limit switch, but instead is using the limit switch information
from the right side of the carriage to its left, this parameter should be set to SHARE. However, if
this carriage has its own left limit switch (and the carriage to its left has a right limit switch), this
parameter should be set to DON'T SHARE. This option might be used when the loaded weight
of an adjacent carriage is significantly different.