57
Adjustment Window
Chapt
er
3
Men
u
Wind
o
w
For the XYZ format signal
You can select from D-Cine XYZ, User Color Temp XYZ
1, User Color Temp XYZ 2, User Color Temp XYZ 3,
User Color Temp XYZ 4 or User Color Temp XYZ 5.
When D-Cine XYZ data is changed, it is displayed as D-
Cine XYZ*.
x:
Displays the default x coordinate.
y:
Displays the default y coordinate.
Input Signal:
Sets the signal to be used for adjusting the
color temperature manually.
Internal:
Select when an internal signal is used.
[External]:
Select when an external signal is used.
Input Signal cannot be selected in the following cases.
Input the 100% white signal.
• When the signal to be displayed is XYZ or HDMI
computer signal
• When Format is set to DVI Computer
Contrast Hold:
Sets whether or not to adjust the color
temperature and contrast (backlight) at the same time.
[On]:
Contrast is not adjusted.
Off:
Contrast is adjusted.
Picture Preset:
The picture adjustment preset data set in
Picture Preset of the Configurations tab window of the
Main Operation, Picture Preset 1 to Picture Preset 5 or
Picture Preset(D-Cine), is displayed.
To change the picture adjustment preset data, select from
Picture Preset 1 to Picture Preset 5 or Picture Preset(D-
Cine) in Picture Preset of the Configurations tab window
of the Main Operation window.
When Contrast is adjusted in Picture Adjustment of the
Controls tab window of the Main Operation window,
Picture Manual is displayed.
For information about the Main Operation window, see
page 44.
b
Start Adjustment
Click to display the color temperature adjustment window.
Destination:
Displays the color temperature data to be
adjusted.
Original Value:
Displays the default setting to be
adjusted.
Input Signal:
Displays the signal to adjust the color
temperature manually.
Current xy:
Displays the x and y coordinates of the color
temperature data to be adjusted.
The displayed chromaticity coordinates x and y are
reference values and are not guaranteed as absolute values.
R/G/B:
Adjusts the R/G/B of the color temperature
data to be adjusted with +/–.
When Contrast Hold is set to On, the adjustable items
are as follows:
R (red)
G (green)
B (blue)
When Contrast Hold is set to Off, the adjustable items
are as follows:
R (red)
G (green)
B (blue)
Contrast (contrast)
To reset x, y, Red, Green and Blue to the value
before adjustment
Click the Reset button of Current xy. The x, y, Red,
Green and Blue are reset to the value before
adjustment.
To reset Contrast to the value before adjustment
Click the Reset button of Contrast.
Contrast Hold
: Displays the Contrast Hold setting in the
Color Temp (Manual) tab window.
Note
Note
Color Temp (Manual)
Destination
D65
D65
0.313
x
0.329
0.303
0.339
y
Internal
Original Value
Input Signal
On
Contrast Hold
---
Picture Preset
Contrast
400
2500
Current xy
R
x
0.317
y
0.333
Reset
Apply
1000
Reset
– +
G
– +
B
– +
0.313
0.323
0.329
0.319
Cancel