Display Function Window
Chapt
er
3
Men
u
Wind
o
w
right, bottom left and bottom right) using the set value of
Pixel Threshold.
Signal Level:
Sets the upper and lower limits of the signal
level.
The signal level to be set is black level 256 and white level
3760 in 12bit conversion value.
Upper Limit (upper limit): 0 to 4095 [3761]
Lower Limit (lower limit): 0 to 4095 [255]
d
Zebra Pattern
Sets the zebra pattern displayed by the gamut error
detection.
When the setting for the zebra pattern is changed, Zebra
Pattern of Black Detail of the Miscellaneous tab window is
also set to the same setting value.
Line:
Sets the direction of the pattern.
[Diagonal Type1]
: Right descending
Diagonal Type2
: Left descending
Modulation:
Sets the amplitude of the pattern display.
Set to 1 to 50. [16]
Miscellaneous Tab Window
This window is used to set the black detail mode and the
synchronization of the output signal from the input
adaptors.
a
Black Detail
Sets the black detail mode.
Clip Indicator:
Sets whether or not to display a zebra
pattern in the clipped portions with high color gradation on
the black detail mode display ([On] or Off).