113
level becomes lower. On the other hand, every
time you push the - button, the sound level
becomes lower and the reference input level
becomes higher.
To specify the reference input level by using the
ten key pad: Proceed as follows to input the
reference input level.
1
Move the cursor to the LVL display and push
the ENTER button.
The unit is ready to accept the numerical value
and the displayed level blinks.
2
S or – using the +/– buttons and enter
the numerical value of the reference input level
using the ten key pad.
You can s or – after you have entered
the numerical value of the reference input
level.
3
Push the ENTER button to execute the entered
numerical value.
If you push the CANCEL button before
pushing the ENTER button, the numerical
value entered is cleared.
Note
The adjustable range of the reference level changes
depending on the PAD setting.
When PAD is set to OFF, the adjustable range of
the reference input level is between –66 to
–20 dBu.
When PAD is set to ON, the adjustable range is
between –36 and +10 dBu.
Even when you enter a numerical value for the
reference input level using the ten key pad, you
cannot specify a value beyond the adjustable range.
To close the MIC AMP menu
Push the MIC AMP button.
The MIC AMP button indicator goes off and the
normal window appears.
SETUP Menu
About the submenus of the SETUP menu
The SETUP menu has the following submenus.
• SYNC
Selects the sampling frequency and sync reference
signal of the SIU-100/100T.
• LED DISPLAY
Sets the display mode of the INPUT monitor display
on the front panel.
• SLOT INFO
Displays the type of option boards inserted in the slots
of the rear panel. Depending on the board displayed,
you can make the settings for operation of the board.
• DI LOCK STATUS
Displays the lock status when boards having AES
digital input are used.
• DI CH STATUS
Display detailed information on the channel status of
the input signal when boards having AES digital input
are used.
• DO CH STATUS
Makes settings related to the channel status of the
output signal when boards having AES digital output
are used.
• MIDI
Performs settings related to recalling scenes when
receiving MIDI input.
• IP
Sets the IP address of the SIU-100/100T to use the
ethernet connector of the SIU-100/100T.
• SIU-RM101
Sets the channel number to be displayed on the SIU-
RM101 when using the SIU-RM101.
• SRAM CLEAR
Resets the operating parameters such as current
routings, to the default settings.
• SYSTEM BACKUP
Stores the settings in use in the non-volatile memory as
backup data. Settings not included in scene
information are also stored.
• SYSTEM RESTORE
Resets the unit to its former status based on
information stored by a SYSTEM BACKUP submenu
operation.
• ROUTING CLEAR
Clears all of routing settings currently being used.