3 Product information
vamp
air
K 12 and K 15
The fan
4
sucks the ambient air (outside air) through
the evaporator
6
and blows it out through the sound-
proofing fins
3
.
The condensate formed during defrosting of the eva-
porator is discharged through the outlet
8
.
Fig. 2-3: Front side with sound insulation strips
Fig. 2-4: Rear side with intake grille
1 Terminal area (electrical connection terminals)
2 Overtemperature reset (OTR)(STB)
[1]
3 Soundproofing slats
4 Fan
5 Evaporators
6 Intake grille
7 Outside temperature sensor
8 Condensate drain
[1]Only when using electric heating element (optional accessory)
Components cooling circuit (without evaporator)
Fig. 2-5_006AY
1 Condenser (plate heat exchanger)
1a Heating circuit flow outlet
1b Heating circuit return inlet
2 Non-return valve
3 Liquid collector
4 Fluid line to evaporator
5 Suction gas line from evaporator
6 Filter dryer
7 Scroll compressor
8 Expansion valve
9 Four-way diverter valve
10 Pressure sensors
Installation manual