7 Electrical connection
7.5.5 Connect RS485 bus
►
Establish the bus cable connection from the dis-
play to the electrical clamping area of the heat
pump.
►
220 Ω resistor in connector X5 (on display).
Display
X5
Terminal area
X5
RS485 A
Pin 1 or 3
A
RS485 B
Pin 2 or 4
B
GND
Pin 5
GND
⏊
7.6 Connect electronic module D1
i
Note on terminal designations in the electronic
module:
O
or
o
stands for
output
,
I
or
i
stands
for
input
.
►
Loosen 4 screws and remove the module cover.
7.6.1 Pinout - overview
i
You can find detailed information about the
connection of the individual components on the
following pages.
Fig. 2-40: electronic module (type
universal module
)
Connection Function
CAN-IN
Bus cable
CAN-OUT Bus cable
X1
Power supply for the electronic module -
230 V AC
X2
230 V AC output (e.g. for further elec-
tronics modules)
i1
Switching contact (input) for heating cir-
cuit
[1]
i2
Temperature sensor storage tank (buffer
tank, drinking water storage tank)
i3
Flow sensor
i4
vamp
air
K 08, K 10: Contact sensor return
i4
vamp
air
K 12, K 15: Flow sensor (made
by Huba Control) - measurement of the
return temperature
i5
Digital input for Smart Grid
[1]
i9
Digital input for Smart Grid
[1]
i15
vamp
air
K 12, K 15: Flow sensor (made
by Huba Control) - measurement of the
flow rate
o1
Primary circuit circulation pump - power
supply
OUT1
Primary circuit circulation pump - control
signal
o2
Three-way ball valve
[1] Only connect potential-free contacts.
7.6.2 Connection of the bus cable
!
CAUTION
–
Danger of destruction of the electronic
module or control components when wired
incorrectly.
–
Bus cable/sensor cable (low voltage) and
power cable (230 V) laid separately.
–
Where a bus cable (with separate earthing
systems) extends over more than one buil-
ding install a CAN bus repeater to gal-
vanically separate the bus (e.g.
SOLARFOCUS Art. 61610).
!
CAUTION
- Depending on the type of elec-
tronic module, note the different versions of the
CAN-IN terminal.
–
Typ
Universal-Modul:
3-pole, A B
⏊
–
Type
heating circuit basic module
and
hea-
ting circuit extension module:
4-pole, + A B
⏊
Installation manual
vampair
27
Содержание vampair K 08
Страница 25: ...7 Electrical connection Installation manual vampair 25 7 4 Electrical connection plan...
Страница 33: ...9 Foundation plan Installation manual vampair 33 Side view of foundation Section A A Fig 2 46...